INSTALLATION INSTRUCTIONS

DESCRIPTION/ FEATURES

WIRING DIRECTIONS

3

SPECIFICATIONS

The PL20R and PLBPC are Wireless Plug Load Controls that are code compliant with 2013 

California Title 24. The powerful 20A Tamper Resistant Smart Duplex Receptacle has 

Controlled and Uncontrolled receptacles, an LED indicator, and a Manual override button. The 

Controlled Plug Load will turn ON when motion is detected by the ceiling sensor and will turn 

off 30 minutes after the room is vacated. The PIR ceiling sensor is battery operated so there is 

no need for expensive in-wall wiring between the sensor and receptacles. Each PIR sensor 

can pair up more than the 6 recommended receptacles with a wireless range up to 24' so it 

can operate in large rooms such as conference rooms and lobbies. 

Hotel guest room: flat screen TV's, floor lamps, task lamps, 

and 

coffee maker

.

Private offices: monitors, desk lamps, desk fan, personal heater, flat screen TV, and printer

.

Breakrooms: toasters, coffee maker, microwaves, flat screen TV

's

, and vending machines

.

Waiting rooms: flat screen TV's, 

and 

table lamp

s.

Copier rooms: monitors, shredders, copier machines, hole punch machines, flat screen TV's

.

COVERAGE

Make sure the sensor's view of the entrances is not blocked by the door 

when it is opened.

Do not mount sensors close to air vents.

Cover the main walkways

Try to avoid having the sensor looking out the door of the space 

WARNING

Turn the POWER OFF at the circuit breaker before 

installing the receptacle

.

Read and understand these instructions before installing.  This device is intended for 

installation in accordance with the National Electric Code and local regulations.  It is 

recommended that a qualified electrician performs this installation.  Make sure to turn off 

the circuit breaker or fuse(s) and make sure power is off before wiring the device.

Use copper wires only. 

Voltage (PL20R)..............................................................................................120VAC, 60HZ, 20A

Operating Temperature ................................................................................................30°to 120°F
Relative Humidity................................................................................20% to 90% non condensing
Operating Frequency...........................................................................................................315MHz
Reception Sensitivity..........................................................................................................-105dBm
Sensor Standby Current………....…..…………......................................................................200uA
Wireless Transmitting Current...................................................................................................5mA
Max Wireless Range..................................................................................................................24ft
Ceiling Sensor Battery Requirement........................................................................2 AA (Included)

PL20R and PLB

PC

Wireless Plug Load Control

The PLBPC provides a 360° coverage pattern. The coverage shown represents walking 

motion at a mounting height of 8ft. For building spaces with lower levels of activity or with 

obstacles and barriers, coverage size my decrease.

Location: 

The PLBPC ceiling sensor should be mounted in a location free of obstruction 

from furniture, plants, walls and vibration. The sensor must be mounted a minimum of 4ft 

away from any air vents (registers). Avoid mounting the sensor close to heat source. 

When mounting directly to a ceiling fixture,the lens of the sensor must be below the 

lowest point of the fixture
The ceiling sensor is designed for a ceiling height or about 8-10 feet. Because of the 

umbrela shaped coverage pattern, mounting above or below the recommended height 

could reduce the coverage range and sensitivity.

Insert wire

s

 through 

the 

terminal holes in the back, then tighten 

terminal 

screws.

Connect 

Black 

HOT

 wire to the HOT terminal (brass screw). 


Connect 

White 

NEUTRAL

 wire to the NEUTRAL terminal (silver screw).

 

Connect GREEN 

or BARE 

wire to the GROUND terminal (green screw).

1

2

IMPORTANT NOTES BEFORE YOU PROCE

ED

:

Check with your electrician for maximum receptacles allowed per branch circuit.

A PLBPC sensor can control PL20R receptacles that are installed on different 

branch circuits.

Exercise extreme caution when using the PLBPC to control appliances. It can be 

activated from a room different than the controlled appliance so an unintentional 

activation may occur if motion is detected. Unattended or unintentional operation 

of connected appliance could result in hazardous conditions.

Automated devices should never be used to supply power to or

 control

 medical

monitor

 and/or life support equipment. 

Ideal Solutions for Wireless 

Plug Load 

Control 

Motor Load............................................................................................................................1/2 HP

Time Delay......................................................................................................................30 minutes