Page 1: ......

Page 2: ...2 2014 Energizer Power Equipment All Rights Reserved Licensed by Energizer Corporation United States of America EZG7250 06 2013 01 series...

Page 3: ...3 series Let s get started You re excited to power up so we ll keep this brief...

Page 4: ...mber to register Take a minute to register this product online at www energizergenerators com This will allow you to request warranty support in the future This manual will show you how to use the gre...

Page 5: ...ZG7250 All information in this publication is based on the latest product information available at the time of print Visit www energizergenerators com for user guide updates and operation notices No p...

Page 6: ...operation assistance and product support is provided by Midland International Inc a licensed manufacturer of En ergizer Power Equipment Please contact us directly for any warranty service questions 1...

Page 7: ...7 series 8 8 9 9 10 11 11 13 14 17 17 18 19 20 21 21 23 24 25 25 25 26 27 28 29 31 32 33 34...

Page 8: ...ons of a poisonous carbon monoxide gas Be careful not to touch the exhaust system compressor pump or discharge tubing during operation due to risk of burns Pay attention to the warning labels The engi...

Page 9: ...n electrical shock Turn off the generator immediately if the device begins to operate abnormally Then disconnect the device and investigate the problem Make sure that the electrical rating of the devi...

Page 10: ...stop the generator set before removing the oil filler cap Only qualified maintenance personnel with knowledge of fuels electricity and machinery hazards should perform maintenance procedures Lubricate...

Page 11: ...hapter 2 Learn About Your Generator This section will show you how to identify key parts of your generator Going over the terminology below will make sure we re on the same page 2 1 Identification of...

Page 12: ...oid short circuit Recharge after use Must be disposed and recycled properly Never disassemble or heat above 50 C Never Incinerate Ne jamais recharger dans un contenant sell nvitez un court circuit Fai...

Page 13: ...ou m me la mort Ne faites pas d marrer ou fonctionner un moteur l int rieur ou dans une aire ferm e m me si les fen tres et les portes sont ouvertes U n l e a d e d G a s o l i n e O n l y D o n otov...

Page 14: ...ttach the two peg stands at the bottom of the frame of the genera tor Tighten the two bolts 6 and two nuts 7 to the lower frame of the generator 3 Place the two wheels 5 on the wheel axle 4 and then s...

Page 15: ...15 series Rubber washers...

Page 16: ...16...

Page 17: ...r is air cooled and may be damaged if ventilation is inadequate 3 1 Checking the Engine Oil Level 5 Ensure the generator is on a level surface 6 Inspect engine oil Take out the oil filler cap and clea...

Page 18: ...and explosive under certain conditions Refuel in a well ventilated area with the engine stopped Do not smoke or allow open flames or sparks in the area where the generator is being refueled or where g...

Page 19: ...nt with soap and water or solvent Squeeze dry and then soak in clean engine oil 3 Squeeze out all excess oil and reinstall Replace the element if it is damaged Check the air filter using the maintenan...

Page 20: ...s secured by using the fastener at the battery terminal 2 Connect the black cabel with the negative terminal of the battery ensure the connection is secured by using the fastener at the battery termin...

Page 21: ...oors and vents These openings can pull in generator exhaust Even when you use a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in your home If yo...

Page 22: ...above the air filter cap on the left side of your generator 3 Disconnect all devices from the outlets on the generator panel Then press the engine switch to the RUN position 4 Grasp the recoil stater...

Page 23: ...W circular saw a 500W drill and a 100W light at the same time 4500W combined However to operate a second 900W saw it will be necessary to disconnect one of the 1500 W heaters 1 Turn off the switches o...

Page 24: ...AVR Your generator is equipped with an Automatic Voltage Regulator which ensures a con stant voltage and present a waveform similar to what you get from the city power grid They are an improvement ov...

Page 25: ...ion Engine Lubricants Inspect Oil Level Replace Air Filter Inspection Cleaning Sediment Cup Cleaning Spark Plug Inspection Cleaning Replacement Valve Clear ance Inspection Adjusting Combustion Chamber...

Page 26: ...n Do not operate this product without an air filter 1 Rotate the knob counterclockwise to release 2 Lift the filter cap to remove from the filter 3 Remove the foam filter 4 If the foam filter is dirty...

Page 27: ...s or on soil Local service shops provide environmentally friendly disposal methods 1 Stop the engine and remove oil filler cap 2 Place a pan under the engine 3 Remove the oil drain screw and allow the...

Page 28: ...d spark plug 1 Disconnect and remove the spark plug using a wrench 2 Inspect the spark plug and clean any dirt from the electrodes with a wire brush If electrodes are worn or show signs of wear replac...

Page 29: ...at a level position in order to prevent spillage Storage Before storing the generator set for an extended period 1 Ensure that the storage area is free of excess humidity and dust 2 Drain the fuel tan...

Page 30: ...drain completely drain and re tighten the drain screw Disconnecting the Electric Start Battery 1 disconnect red cable from the bositive battery terminal 2 disconnect black cable from the negative batt...

Page 31: ...in closed position Open choke Dirty air filter Clean air filter Rich fuel mixture Contact customer service Engine stops No fuel Refill fuel tank Not enough oil Add more oil Engine has dif ficulty idli...

Page 32: ...ement cm3 420cc Ignition mode Transistor Controlled Ignition Starting mode Recoil Start Electric Start Max Output W rpm 7250 3600 Fuel tank capacity 29L 25L CA model Oil capacity 1 1L 10W30 Fuel Type...

Page 33: ...33 series Chapter 8 Wiring Diagram...

Page 34: ...components or workmanship during the three 3 Year period The warranty coverage is continual from the initial date of purchase and does not restart at anytime under any circumstances This limited warr...

Page 35: ...arranty EXCLUSIONS NOT COVERED BY THIS LIMITED WARRANTY 1 Normal engine alternator wear 2 Damage caused by lack of maintenance as described in the Energizer User Guides or negligence by using improper...

Page 36: ...Air filter element Ignition Flywheel magneto Ignition pulse generator Crankshaft position sensor Power coil Ignition coil assembly Ignition control mod ule Spark plug cap Spark plug Crankcase Emission...

Page 37: ...land Power Inc are pleased to explain the emission control system warranty on your Midland Power Inc engine In California new spark ignited small off road equipment engines must be designed built and...

Page 38: ...38...

Page 39: ...your product packaging The store date of purchase and product purchase should be clearly visible on the receipt copy You may also register online by visiting our website www energizergenerators com I...

Page 40: ...40...

Page 41: ...ued warranty and service support Warranty support cannot be provided without registration from original date of purchase and after transfer of ownership This transfer form must be completed on or befo...

Page 42: ...42 Enjoy Be sure to check energizergenerators com monthly for updates regarding your generator...

Page 43: ...43 series series...

Page 44: ...44 TM...