6.
TECHNICAL FEATURES
Unit
200
250
300
ST
ORAG
E
W
AT
ER
HE
AT
ER
Dry weight
Kg / lb
73 / 160
83 / 182.9
95 / 209.4
Volume
Lts / gal
200 / 52,8
250 / 66
300 / 79.25
Type of internal protection
-
Enamelled
Cathodic protection
-
Magnesium anode (1”1/4 Female)
Hydraulic joints
(Cold|Hot|TPR valve|Recirculation)
in
¾” Male
|
¾” Male
|
½” Female
|
¾” Female
Maximum pressure
bar / psi
6 / 87
Test pressure
bar / psi
10 / 145
Maximum water temperature
°C/°F
80 / 176
Recommended water temperature
°C/°F
60 / 140
THE
RMO
DI
N
AMI
C
S
OL
AR
P
AN
EL
Material
-
Solokote Hydrofobic Anodized Aluminium
Dimensions (L x A x e)
mm / ft
2000 x 800 x 20 / 6.56x 2.63 x 0.065
Weight
Kg / lb
8 / 17,6
Maximum working pressure
bar / psi
10 / 145
Test pressure
bar / psi
12 / 174
Maximum exposure temperature
°C /°F
120 / 248
Minimum running temperature
°C/°F
- 5 / 23
Minimum exposure temperature
°C/°F
- 40 / -40
THE
RMO
DYN
AMI
C
G
ROUP
Width
mm / ft
320 / 1.049
Height
mm / ft
710 / 2.329
Depth
mm / ft
280 / 0.918
Weight
Kg / lb
18 / 40
Absorbed power (Average/Max)
W
390 - 550
Thermal power (Average/Max)
W
1690 / 2900
Element
W
1500
Compressor Type
-
Danfoss
Compressor Noise Level
dB
39
C
OO
LI
N
G
C
OUP
LI
N
G
S
Cooling Fluid / Amount
- / Kg / lb
R134a / 1 / 2,2
Piping Material
-
Copper (DHP ISO1337)
Line of liquid
in
1/4”
Line of aspiration
in
3/8”
P
OW
ER
SUP
P
LY
Power feed
VAC / Hz
220-240 / 50-60
Current
A
15