- Connection to controller display
•
The power supply must go through the wire access and be connected to
the power supply terminals in the controlling box. Then connect the 3-
signal wire plugs of the wire controller and main controller.
•
The appliance must be fitted with means for disconnection from the
supply mains having a contact separation in all poles that provide full
disconnection under overvoltage category III conditions, and these
means must be incorporated in the fixed wiring in accordance with the
wiring rules.
•
An all-pole disconnection switch having a contact separation of at least
3mm in all poles should be connected in fixed wiring.
•
The wiring must be completed by professional technicians in accordance
with circuit diagram.
•
Power supply circuit must have earth wire, the earth wire of power should
be connected with external earth wire safely. And the external earth wire
must be in order.
•
The creepage protection device must be settled in accordance with the
relevant national technical standards for electronic equipment.
•
The power wire and signal wire should be neatly arranged. High voltage
wire and low voltage wire must be separated and free from any
interference, and they must be free from any pipe and valves of the unit.
•
When all the wiring is completed, the power can only be connected after
a double check. Power Specifications.
ATTENTION: The Aquapura 16T (inverter R 5-18) has a
phase sequencer.
If the display does not turn on, please change one of the phases.
15.10
Electrical wiring
Model
Power source
Max. current
* Power
source cable
section
Inv. R 8-12
220/240V~ /50Hz
21,5 A
6mm²
Inv. R 5-18
220/240V~ /50Hz
33,2 A
6mm²
Inv. R 5-18
400V~/ 50Hz
12,5 A
2,5 mm²
*
The above wire sizes are
selected at the maximum current of the unit
according to the European Standard considering a cable length of 10
meters.
NOTE:
Follow local codes and regulations when selecting field wires, circuit
breakers and earth leakage breakers.