[0203072TSS] TSS-D Battery Chargers r1
User's Manual
AC VOLTAGE SELECTION 1 x 208/240 & 480 V
The input voltage setting of the charger is made using two devices:
1) BOARD FOR INPUT VOLTAGE SELECTION (BVS)
(two selectable ranges: 200-250V or 440-524V);
2) PLUGS FOR INPUT VOLTAGE ADJUSTMENT
(five taps within the selected range, see next chapter).
The BOARD FOR INPUT VOLTAGE SELECTION has three metal bars, to be connected in one
of the two configurations represented on the picture inside the charger.
PROCEDURE:
•
Check that the charger is disconnected from AC input and battery;
•
Open the cabinet and remove the plastic protection over the BVS;
•
Remove the metal bars and position them in the correct configuration.
•
Fix the nuts carefully;
•
Mount the plastic protection over the BVS;
•
Close the cabinet.
Metal bars in position 208-240 Vac
Metal bars in position 450-510 Vac
AC INPUT VOLTAGE ADJUSTMENT
The local AC input voltage must be measured with an adequate voltmeter, then the charger
input must be adjusted by moving the three wires marked with the letters A, B, C on the
PLUGS FOR INPUT VOLTAGE ADJUSTMENT.
PROCEDURE:
•
Check that the charger is disconnected from AC input and battery;
•
Open the cabinet;
•
Disconnect the wires A, B, C from the original position;
•
Connect the wire A, B, C to the desired position.
•
Close the cabinet.
__________________________________________________________________________________________________________________________________________________
Page 8/19