ENERDAN BT-C700 Operation Instructions Manual Download Page 1

Battery Charger BT-C700 

Operation Instructions 

 

 

General Information 

● The product is intended to charge and discharge NiCad or NiMH rechargeable

 

   

   

 

 

 

 

 

 

 

batteries. It provides four independent charging slots for AA/AAA rechargeable

   

 

 

 

 

 

 

 

 

batteries. 

● The charger can also optimize and test the maximum capacity of rechargeable

 

 

 

 

 

 

 

 

 

   

 

batteries. Each charging slot has its own display to show various information, such

 

 

 

 

 

 

 

   

 

 

 

 

as, charging current, battery voltage, charged/discharged capacity, battery internal

 

 

 

 

 

 

 

 

 

resistance and elapsed charging time.  

● The charging current can be selected from 200mA to 1000mA. If 4 batteries are

 

 

 

 

 

 

 

   

     

 

 

being charged, then the maximum current for each slot will be limited to 700mA. If

 

 

 

 

 

 

 

 

 

 

 

   

   

there is no battery in slots 2 or 3, then the maximum current in slot 1 and 4 can be

   

 

   

       

 

 

 

   

   

   

 

 

selected up to 1000mA.  

● The charger can charge simultaneously batteries of different types and sizes and

 

 

 

 

 

   

 

 

 

 

 

with different capacity. It also includes the Minus Delta Voltage (-ΔV) function, which

 

 

   

 

 

 

 

 

 

 

 

 

monitors the voltage over the charging cycle. When a battery is fully charged, the

 

 

 

 

 

 

 

   

   

 

 

 

charger will switch to trickle charging automatically. Therefore the battery will be kept

 

 

   

 

 

 

 

 

 

   

 

at its optimum capacity.  

 

Distributed by ENERdan GmbH | Max-Planck-Straße 3, D-12489 Berlin, Germany 

[email protected]

 | +49 - (0)30 – 6392-80400 | www.enerdan.de

 

 
 

Summary of Contents for BT-C700

Page 1: ...nt can be selected from 200mA to 1000mA If 4 batteries are being charged then the maximum current for each slot will be limited to 700mA If there is no battery in slots 2 or 3 then the maximum current in slot 1 and 4 can be selected up to 1000mA The charger can charge simultaneously batteries of different types and sizes and with different capacity It also includes the Minus Delta Voltage ΔV funct...

Page 2: ...nversion and or modification of the device are inadmissible because of safety and approval reasons CE Any usage other than described in this manual is not permitted and can damage the product and lead to associated risks such as short circuit fire electric shock etc Please read the operating instructions thoroughly and keep them for future reference The charger has its backlight turned on after ea...

Page 3: ... shown until any batteries are inserted image 3 Operation Once a rechargeable battery is inserted its present voltage for example 1 12V will be displayed for 3 seconds then 400mA default charging current will be shown on display for another 3 seconds Image 4 If MODE or CURRENT button image 5 is not pressed during these 6 seconds the charging process will start During the first 6 second time if any...

Page 4: ...on for 2 seconds to start working mode selection for all four battery slots Press the MODE button subsequently to toggle between the CHARGE DISCHARGE TEST QUICK TEST and REFRESH modes Image 6 When a particular slot working mode needs to be changed detach the battery from the charger and insert it into the slot again while that selected slot LCD display content is flashing press MODE button to choo...

Page 5: ...hargeable battery is discharged to a preset battery voltage 0 9V Once the discharge is finished the total accumulated discharging capacity will be displayed at mAh showing how much energy is discharged from the battery which is always referring to the accumulated discharging capacity No trickle charge current will be applied after discharge cycle is finished REFRESH Mode The rechargeable battery i...

Page 6: ...r 500 milliohms it means these batteries are not sufficient for supplying power to high current loads such as digital cameras etc However they can still be used for low energy loads such as clocks remote controllers etc Always use batteries with more or less similar internal resistance when they are used in serial to achieve maximum battery life Alkaline and other 1 5V batteries can be tested on t...

Page 7: ...Technical Specifications Input Voltage 12V 16VDC Power Supply Input 100 240V 50 60Hz Output 12V DC 1 0A Charging Current Range 200 300 400 500 700 1000 mA Maximal Charging Capacity 20000 mA Operation Temperatures 0 40 C Maintenance The device requires no particular maintenance but should be cleaned occasionally When cleaning the device must be disconnected from any power source Use dry and soft cl...

Page 8: ... even destroy the product Wait until the product adapts to the new ambient temperature before use Sufficient ventilation is essential when operating the charger Never cover the ventilating slots of the charger Please take precautions especially when ambient temperature is over 35 degrees Celsius and charging current rate is over 0 5C If higher charging current applied it is easier to build up temp...

Page 9: ...Max Planck Straße 3 D 12489 Berlin Germany Email sales enerdan de Tel 49 0 30 6392 80400 More Information and products at www enerpower de Distributed by ENERdan GmbH Max Planck Straße 3 D 12489 Berlin Germany sales enerdan de 49 0 30 6392 80400 www enerdan de ...