background image

EN

User Manual 

Ethernet over Coax Transceiver 

Data/Power supply 270Mbps, 

57VDC power input

IAM-6MC1001M0A

Summary of Contents for 221273

Page 1: ...EN User Manual Ethernet over Coax Transceiver Data Power supply 270Mbps 57VDC power input IAM 6MC1001M0A...

Page 2: ...Videor E Hartig GmbH Use only original spare parts and accessories from Videor E Hartig GmbH The housing should only be cleaned using a mild domestic cleaning agent Never use solvents or petrol as th...

Page 3: ...1 Warranty 7 2 Pre field verification 8 2 1 Checktransmissionline 8 2 2 Check grounding and potential difference 12 2 3 Siteenvironmentreview 12 3 Equipment Installation Guide 13 3 1 Selectionofinstal...

Page 4: ...on utilizing the existing CCTV cable Coax UTP 2wire Etc With long distance transmission feature the device makes to overcome 100 meters distance limitation easily and reduces the construction cost sig...

Page 5: ...4 1 4 Hardware Overview BNC connector DC Power Jack Status LED indicator Join Button DC OUT LED Terminal Block Right Left EPoC Transceiver EPoC Transceiver RJ45 DC OUT ON OFF Switch Note The Join Butt...

Page 6: ...ed PWR BNC Join Quality PWR LED are on 5 Fix up EPoC Transceiver where it should be placed 6 Connect the UTP LAN cable between EPoC Transceiver and NVR first and then between EPoC Transceiver and came...

Page 7: ...on Rate 270Mbps Full Duplex PHY 500Mbps Transmission Distance Ethernet up to 2 4Km RG 6 PoE PoC up to 1 2Km RG 6 7W camera LED Indication Ethernet 1 x Data Green EPoC 1 x BNC Join Green Power 1 x PWR...

Page 8: ...Do not put any sticker or paint on it If this device is defective or malfunctioning please unplug the power adapter immediately and contact dealer or service center Use only rated 56V power adapter sp...

Page 9: ...fication 2 1 Check transmission line 2 1 1 Transmission line type EPoC Ethernet over Coax Applicable Coaxial cable 3C 5C 7C 10C RG58 RG59 RG6 RG11 KX6 KX100 etc Ethernet over Coax Transceiver 2 Wire U...

Page 10: ...it means the cable might be open 5 If the value is lower than the expected loop resistance value the cable might be shorted Normal loop resistance of the cable in case of RG59 is about 8 10 100 meter...

Page 11: ...dedicated connector when connecting cables It is not recommended to mix different types of cables When 50 and 75 cable are used in combination or 50 BNC is applied to 75 cable the impedance between t...

Page 12: ...ther side In case of Copper covered steel cable the cable loop resistance can be significantly increased and It is strongly recommended to check the cable loop resistance before installation because i...

Page 13: ...ly Therefore it is necessary to make sure that the end device is normally grounded and that there s the potential difference between the end device and transmitter 2 3 Site environment review Check th...

Page 14: ...low the coaxial cables from existing analogue CCTV system to be re used for network camera connection Reusing existing coax for IP cameras can cut installation costs and save installation time signifi...

Page 15: ...mission rate Transceiver Transmission rate Mbps by product configuration DaisyChain Distance 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 200m 257 126 76 55 41 31 25 20 600m 254 115 56 32 22 16 12 10 1 200m 140 60...

Page 16: ...Transceiver Indicator Color Function BNC Join EPoC Devices connected PWR 56VDC input connected Quality LINK Good data connection Poor data connection PWR Good power supply condition Additional adapter...

Page 17: ...tial difference between the camera body or metal surface and EPoC transmitter If there s potential difference on the camera and DC ground of the EPoC transmitter it is necessary to isolate camera body...

Page 18: ...to the installation distance for each product and transmission medium What is the basic configuration NVR Rx EPoC ADC Tx EPoC DAC IP camera are configured as one set Therefore you need two EPoCs Tx Rx...

Page 19: ...ion medium is used in the field Mostly the coaxial cable is RG 59 5C HFBT 75 the twisted pair cable is Cat 5e UTP I want to know how to connect to a Coaxial cable The coaxial cable must be connected u...

Page 20: ...alog camera PTZ control is not enabled on the IP camera EPoC only converts the video and control signals sent and received between the NVR and the IP camera DAC ADC EPoC recognizes only digital signal...

Page 21: ...LED is blinking check that the DC OUT switch is ON and the DC OUT LED is green since the IP camera can not powered by 12VDC output If red light on the power quality LED is on 48 57VDC power from Rx E...

Page 22: ...ibution through special ised trade channels only VIDEOR E Hartig GmbH Carl Zeiss Stra e 8 63322 R dermark Germany Tel 49 0 6074 888 0 Fax 49 0 6074 888 100 www videor com www eneo security com Technic...

Reviews: