Maintenance
Maintenance of the alternator is described in this section.
Only personnel from the manufacturer may carry out mainte-
nance or repair work not described in this section.
5.1
Maintenance plan
The maintenance work specified in this summary must be
carried out after the indicated time intervals.
Maintenance work
Time interval in operating hours [h]
after 8 h every 8
h /
daily
every 25
h /
annual-
ly
every 50
h /
annual-
ly
every
100 h /
annual-
ly
annual-
ly
Checking the electrical safety
before each start-up
Checking the oil
X
Change the oil
X
3)
(X)
1)
Change oil filter
X
Cleaning the air filter
(X)
2)
Clean area around mufflers,
linkages, and springs
X
Exchange spark plugs
X
Change the fuel filter
X
Check fit of screws, nuts, and
bolts
X
Check condition and tightness
of the fuel hoses and connec-
tions.
X
Table 5.1: Generator maintenance plan
1) When operating under a heavy load or at high environmental tempera-
tures at short intervals.
2) Clean more frequently when used in a dusty environment or in the
presence of foreign particles in the air or for longer use in high,
dry grass.
3) First time
Summary of Contents for ESE 1306 DHG-GT ES Duplex
Page 10: ...General information 10 ESE 1306 1506 Version September 2013 Notes...
Page 24: ...24 ESE 1306 1506 Version September 2013 Notes...
Page 33: ...Status September 2013 ESE 1306 1506 33 Notes...
Page 44: ...44 ESE 1306 1506 Version September 2013 Notes...
Page 48: ...48 ESE 1306 1506 Version September 2013 Notes...