35
Commissioning
NOTICE!
Use of wrong or outdated fuel damages or destroys the engine.
► Only use the fuel displayed on the sign (Tab. 3-1 ).
► Observe the possibly enclosed documentation for the fuel release of the en-
gine manufacturer
► Observe the shelf life of the fuel according to the supplier.
► Observe the engine operating manual.
Refuelling the gen-
erator
1. Unscrew the tank cover Fig. 6-2 .
2. Insert the filler nozzle into the filling opening.
3. Fill with fuel slowly and evenly.
4. Take note of the tank's fuel level indicator Fig. 6-2 as well as the fuel level at
the filling opening to ensure that you do not overfill the tank.
5. Remove the filler nozzle.
6. Refit the tank cover.
The generator is now refuelled.
7.5
Starting the generator
Starting the generator for manual operation and with fuel supplied from its
own tank is explained here.
DANGER!
Leaking engine oil and fuel can burn or explode.
A risk of suffering severe even deadly burns.
► Prevent engine oil or fuel from leaking out.
► Remove leaked operating fluids immediately and appropriately.
► Never use an additional start aid.
► Smoking, naked flames and sparks are forbidden.
DANGER!
Engine exhaust gases contain poisonous and partially invisible gases such
as carbon monoxide (CO) and carbon dioxide (CO2).
Risk of death due to poisoning or asphyxiation.
► Ensure that there is good ventilation during the whole period of operation.
► Only operate the generator in the open.
► Never direct the exhaust gases into rooms or pits.
Summary of Contents for ECO Power Line ESE 3000 BS
Page 30: ...30 Description of the device NOTES...
Page 56: ...56 Replacement parts NOTES...
Page 57: ...57 Wiring diagram 14 Wiring diagram...