14.10 Expert → Measurement → Sensor trim
Lo trim measured
Write permission
Parameter is read only. Only Hauser Service has write permission.
Description
Displays the reference pressure present to be accepted for the lower calibration point.
Hi trim measured
Write permission
Parameter is read only. Only Hauser Service has write permission.
Description
Displays the reference pressure present to be accepted for the upper calibration point.
Lo trim sensor
Write permission
No write permissions. Parameter is read only.
Description
Sensor module recalibration by entering a target pressure while simultaneously and
automatically accepting a reference pressure present for the lower calibration point.
Hi trim sensor
Write permission
No write permissions. Parameter is read only.
Description
Sensor module recalibration by entering a target pressure while simultaneously and
automatically accepting a reference pressure present for the upper calibration point.