Solimotion FTR16, FTR20

XA02804F-A

10

Hauser

Safety instruc-

tions: Installation

4

 

3

 

 

 

 

2

                                                           4

1

A

-  .

5

0000000148

A  Zone 21

 

Potential equalization

 

Pipeline (Zone 20, Zone 21)

 

FTR16, FTR20

 

Potential matching line

 

Power and signal circuits

• Pay attention to the installation and safety instructions in the Opera-

ting Instructions.

• Observe maximum process conditions in accordance with associated 

Operating Instructions of the manufacturer.

Device type FTR16

• 

The cables must be firmly laid and effectively protected against 

damage.

• The relevant installation regulations must be adhered to.

• Avoid direct radiation with high UV components (sunlight), mount 

the unit in a protected place or use a weather protective cover.

• 

M12 plugs may only be opened or closed in a sufficiently clean envi

-

ronment.

• Connectors must always be sealed with a counterpart. They may be 

left open in the field only briefly for servicing purposes.

• 

Secure the connector by tightening the nut sufficiently.

• Tightening torque approx. 1.2 to 1.5 Nm. This tightening torque is 

ensured as follows: Hand-fasten the coupling nut (0.4 to 0.5 Nm). 

Then turn by 3 notches using a open wrench across the flats 14.

Summary of Contents for Solimotion FTR16

Page 1: ...71562721 Products Solutions Services Safety Instructions Solimotion FTR16 FTR20 ATEX II 1 2 D Ex ta tb IIIC T200 102 C Da Db II 2 D Ex tb IIIC T200 102 C Db IECEx Ex ta tb IIIC T200 102 C Da Db Ex tb...

Page 2: ......

Page 3: ...documentation 4 Manufacturer s certificates 4 Manufacturer address 5 Other standards 5 Extended order code 5 Safety instructions General 9 Safety instructions Specific conditions of use 9 Safety instr...

Page 4: ...the following Operating Instruc tions BA01136F BA02155F Supplementary documentation Explosion protection brochure CP00021Z 11 The Explosion protection brochure is available In the download area of the...

Page 5: ...losion prevention and pro tection Part 1 Basic concepts and methodology Extended order code The extended order code is indicated on the nameplate which is affixed to the device in such a way that it i...

Page 6: ...in the following tables These tables describe the individual positions and IDs specific to hazardous locations within the extended order code Extended order code Solimotion The following information...

Page 7: ...on selected Description FTR16 QM Connecting cable M12A Ex 5m PUR right angle socket right angle plug QN Connecting cable M12A Ex 10m PUR right angle socket right angle plug QO Connection cable socket...

Page 8: ...15 stainless steel hygiene IP66 C F15 stainless steel hygiene IP66 sight glass D F34 aluminum IP66 E F34 aluminum IP66 sight glass Position 5 electrical connection Option selected Description FTR20 A...

Page 9: ...edia to which the process wetted materials are adequately resistant Avoid electrostatic charge from plastic surfaces e g housing special paint additional labels attached from insulated capacitors e g...

Page 10: ...mly laid and effectively protected against damage The relevant installation regulations must be adhered to Avoid direct radiation with high UV components sunlight mount the unit in a protected place o...

Page 11: ...In the event of potentially explosive vapor air mixtures operate the device only under atmospheric conditions Temperature FTR16 20 to 60 C 4 to 140 F FTR20 40 to 70 C 40 to 158 F Pressure 0 5 to 6 8 b...

Page 12: ...Solimotion FTR16 FTR20 XA02804F A 12 Endress Hauser Connecting cable FTR16 Max 5 wire Total capacity 100 nF FTR20 Maximum 500 m per connection Ci 200 pF m Li 1 H m or 30 H...

Page 13: ...Solimotion FTR16 FTR20 XA02804F A Endress Hauser 13...

Page 14: ...Solimotion FTR16 FTR20 XA02804F A 14 Endress Hauser...

Page 15: ...Solimotion FTR16 FTR20 XA02804F A Endress Hauser 15...

Page 16: ...www addresses endress com 71518769 71518769...

Reviews: