![Endress+Hauser RA33 Operating Instructions Manual Download Page 21](http://html.mh-extra.com/html/endress-hauser/ra33/ra33_operating-instructions-manual_2407412021.webp)
Batch Controller RA33
Operation
Hauser
21
5
Operation
5.1
General notes for operation
The batch controller can be configured using keys or using the "FieldCare" operating software.
The operating software, including the interface cable, is available as an order option, i.e. it is not
part of the basic scope of delivery.
The configuration is locked if the device is locked by the locking switch or the user code.
5.2
Display and operating elements
a0014276
Fig. 22:
Display and operating elements of the batch controller
1
LED green, "Operation"
2
LED red, "Fault indicator"
Function keys:
3
Start
4
Stop
5
Numerical keypad
6
Start printing
Interface:
7
USB connection for configuration
Operating keys:
8
-, +, E
Display:
9160 x80 DOT matrix display
!
Note!
Green LED for voltage, red LED for alarm/error. Green LED is always illuminated as soon as power
is supplied to the device.
Slow flashing of the red LED (approx. 0.5 Hz): the device has been put into bootloader mode.
Fast flashing of the red LED (approx. 2 Hz): in normal operation: maintenance required. During
firmware update: data transmission active.
Red LED illuminated constantly: device error.