11 Description of device functions
Prosonic Flow 92
80
EHauser
11.5.1
Group SYSTEM SETUP
System Setup
Þ
Function
System Setup
Set Date/Time
Use this function to set the actual date and the actual local time.
Remember to change the time if your country changes between summer/
winter time.
User input:
YY-MM-DD – hh:mm:ss
Date and time will be stored by the internal back-up battery.
Baud Rate
(Communication)
Use this function to set the appropriate baud rate for transmitting the values
to a computer.
Options:
300 – 600 – 1200 – 2400 – 4800 – 9600
Factory setting:
300
Parity
(Communication)
Use this function to set the parity for communication.
Options:
NONE – EVEN – ODD
Factory setting:
NONE
Stop Bits
(Communication)
Use this function to set the stop bit for communication.
Options:
1 BIT – 2 BITS
Factory setting:
1 BIT
System Units
Use this function to set the system unit needed.
Options:
METRIC – US
Caution!
To make the setting active, switch off the device briefly and then switch it on
again. When the device is switched on again, the units of the system unit
selected are adjusted.
Factory setting:
METRIC
Summary of Contents for prosonic flow 92
Page 4: ...Brief operating instructions Prosonic Flow 92 4 Endress Hauser...
Page 12: ...2 Identification Prosonic Flow 92 12 Endress Hauser...
Page 26: ...3 Installation Prosonic Flow 92 26 Endress Hauser...
Page 34: ...4 Wiring Prosonic Flow 92 34 Endress Hauser...
Page 40: ...5 Operation Prosonic Flow 92 40 Endress Hauser...
Page 46: ...7 Maintenance Prosonic Flow 92 46 Endress Hauser...