3 Installation
Proline Prosonic Flow 90
22
Hauser
3.3.4
Installing the measuring sensors Prosonic Flow W/P
(clamp-on)
1 traverse version
1.
Fix a tensioning band for small or large nominal diameters as described on Page 18. Install the
second tensioning band (threaded stud on the opposite side). The second tensioning band must
still be moveable.
2.
Determine the sensor distance and the wire length.
!
Note!
To determine the sensor distance and the wire length use:
– the “Sensor Installation” Quick Setup menu if the measuring device has a local operation.
Use the Quick Setup as described on Page 64. The sensor distance is shown in the SENSOR
DISTANCE function and the wire length is shown in the WIRE LENGTH function. The
transmitter has to be installed and connected to the power supply to carry out the “Sensor
Installation” Quick Setup.
– the procedure described on Page 67 ff. if the measuring device has no local operation.
3.
Enter the wire length on both halves of the wire.
A0001112
Fig. 14:
Marking the determined wire length on the wire measurement equipment (SL = wire length)
4.
Push the cable lug and the fixer over the first threaded stud. Lead each wire along one side of
the pipe. Push the cable lug and the fixer over the second threaded stud. Pull in the threaded
stud with the tensioning band until both wires are the same length.
5.
Fix the tensioning band. Loosen the Phillips screws of the fixing parts. Remove the wires.
A0001113
Fig. 15:
Use of the wire measuring equipment for positioning of threaded studs
1
2
3
4
5
6
7
8
9
10
11
SL
Summary of Contents for Prosonic Flow 90
Page 4: ...Brief operating instructions Proline Prosonic Flow 90 4 Endress Hauser...
Page 42: ...4 Wiring Proline Prosonic Flow 90 42 Endress Hauser...
Page 62: ...5 Operation Proline Prosonic Flow 90 62 Endress Hauser...
Page 74: ...7 Maintenance Proline Prosonic Flow 90 74 Endress Hauser...
Page 78: ...8 Accessories Proline Prosonic Flow 90 78 Endress Hauser...
Page 94: ...9 Trouble shooting Proline Prosonic Flow 90 94 Endress Hauser...
Page 108: ...10 Technical data Proline Prosonic Flow 90 108 Endress Hauser...
Page 112: ...Index Proline Prosonic Flow 90 112 Endress Hauser...
Page 114: ...www endress com worldwide BA068D 06 en 11 04 50099981 FM SGLM6 0...