2 Identification
Proline Prosonic Flow 90
10
Hauser
2.1.2
Nameplate of the Prosonic Flow W/P sensors
A0001101
Fig. 2:
Nameplate specifications for the “Prosonic Flow W” sensors (example)
1
Ordering code / serial number: See the specifications on the order confirmation for the meanings of the
individual letters and digits.
2
Sensor type
3
Range of nominal diameters: DN 100...4000
4
Max. fluid temperature range:
–
20 °C (
–
4 °F) ...
+
80 °C (
+
175 °F)
5
Reserved for information on special products
6
Degree of protection
7
Ambient temperature range
8
Data on explosion protection
Refer to the specific additional Ex documentation for detailed information.
Please do not hesitate to contact your Endress
+
Hauser sales office if you have any questions.
2.1.3
Nameplate of the Prosonic Flow U sensors
A0001102
Fig. 3:
Nameplate specifications for the “Prosonic Flow U” sensors (example)
1
Ordering code / serial number: See the specifications on the order confirmation for the meanings of the
individual letters and digits.
2
Sensor type
3
Range of nominal diameters: DN 15...100
4
Max. fluid temperature range:
–
20 °C (
–
4 °F) ...
+
80 °C (
+
175 °F)
5
Degree of protection
6
Ambient temperature range:
–
20 °C (
–
4 °F) ... v60 °C (
+
140 °F)
7
Data on explosion protection
Refer to the specific additional Ex documentation for detailed information.
Please do not hesitate to contact your Endress
+
Hauser sales office if you have any questions.
II3G
FEK0924-0001
EEx nL IIC/IIB T6-T1
HAUSER
CH-4153
R
einach
TYPE 4X
NEMA
IP67
Tamb/Tumg:-20°C..+60°C
control dwg. of transmitter
For Installation refer to
CL.II, Div.1, GP. EFG, CL.III
Dust-Ignitionproof for
CL.I, Div.2, GP. ABCD
APPROVED
FM
PROSONIC FLOW W
XXXXX-XXXXXXXXXXXX
HAUSER
W-CL-1F-L-B
12345678901 RY
-20°C (-4°F) ... +80°C (+175°F)
Order Code:
DN100 - DN4000
Type:
Ser.No.:
i
2001
06/a3/....
XA0..D/
OPEN
CLOSE
1
2
3
4
5
7
8
6
1
2
4
6
7
5
3
DN15 - DN100
-20°C (-4°F) ... +60°C (+140°F)
-20°C (-4°F) ... +80°C (+175°F)
T amb.:
TM:
Type:
U-CL-2F-L-A
i
IP54
CH 1
Order Code:
PROSONIC FLOW U
HAUSER
Ser.No.:
93UA1-XXXXXXXXXXXX
12345678901
For Installation refer to control dwg. of transmitter
CL.I, Div.2, GP. ABCD
CL.I, Zone 2 IIC T6-T1
APPROVED
FM
Summary of Contents for Prosonic Flow 90
Page 4: ...Brief operating instructions Proline Prosonic Flow 90 4 Endress Hauser...
Page 42: ...4 Wiring Proline Prosonic Flow 90 42 Endress Hauser...
Page 62: ...5 Operation Proline Prosonic Flow 90 62 Endress Hauser...
Page 74: ...7 Maintenance Proline Prosonic Flow 90 74 Endress Hauser...
Page 78: ...8 Accessories Proline Prosonic Flow 90 78 Endress Hauser...
Page 94: ...9 Trouble shooting Proline Prosonic Flow 90 94 Endress Hauser...
Page 108: ...10 Technical data Proline Prosonic Flow 90 108 Endress Hauser...
Page 112: ...Index Proline Prosonic Flow 90 112 Endress Hauser...
Page 114: ...www endress com worldwide BA068D 06 en 11 04 50099981 FM SGLM6 0...