Proline t-mass A 150 HART
Operation
Hauser
77
Totalizer value
One of the following options is
selected in the
Assign process
variable
parameter of the
Totalizer
submenu:
• Mass flow
• Corrected volume flow
• FAD volume flow
Displays the current
totalizer counter value.
Floating-point number
with sign
Totalizer overflow
One of the following options is
selected in the
Assign process
variable
parameter of the
Totalizer
submenu:
• Mass flow
• Corrected volume flow
• FAD volume flow
Displays the number of
totalizer overflows.
Value range:
0 to 32
000
Integer
11.3.3 Output values
The
Output values
submenu contains all the parameters needed to display the current
measured values for every output.
Navigation path
"Diagnostics" menu → Measured values → Output values
Structure of the submenu
Output values
→
Output current
Pulse output
Output frequency
Switch status
Parameter overview with brief description
Parameter
Prerequisite
Description
Display
Output current
-
Displays the current
current value of the
current output.
3.6 to 22.5 mA
Pulse output
Pulse
must be selected as the
operating mode.
Displays the current
value of the pulse
output.
Positive floating-point
number
Output frequency
Frequency
must be selected as the
operating mode.
Displays the current
value of the frequency
output.
0.0 to 1
000 Hz
(Up to 1
250 Hz in the
error mode)
Switch status
Switch
must be selected as the
operating mode.
Displays the current
switch output status.
• Open
• Closed