Operation
11.1 Adjusting the operating language
See the "Commissioning" section for information on how to set the operating language
11.2 Configuring the display
• Basic settings for local display
• Advanced settings for local display → 53
11.2.1 Navigation path
"Display/operat." menu
"Display" submenu
Display
→
Format display
Contrast display
Display interval
11.2.2 Parameter overview with brief description
Parameter
Description
Selection/
User entry
Factory setting
Format display
Select how measured
values are shown on the
display.
• 1 value, max. size
• 1 ba 1 value
• 2 values
• 1 value large + 2 values
• 4 values
1 value, max. size
Contrast display
Adjust the contrast of the
local display to ambient
conditions (reading
angle).
20 to 50 %
30 %
Display interval
Set time measured values
are shown on display if
display alternates
between values.
1 to 10
5
11.3 Reading measured values
You can read all measured values using the
Measured values
menu.
Navigation path
Diagnostics → Measured values
11.3.1 Process variables
The
Process variables
submenu contains all the parameters needed to display the current
measured values for every process variable.