Factory setting
Select gas type
Select the gas type for the
measurement application.
Gas type choose list
• Air
• Argon Ar
• Carbon dioxide CO2
• Nitrogen N2
Air
10.4.2 Specifying the process pressure
Navigation path
"Setup" menu → Process pressure
Parameter overview with brief description
Parameter/
Description
Selection/
User entry
Factory setting
Process pressure
Process pressure value for
calculating pressure-dependent gas
properties
0.5 to 41.6 bar a
(7.3 to 603 psi a)
Country-dependent:
1.0130 bar a
(14.692 psi a)
10.4.3 Determining the installation factor
Navigation path
"Setup" menu → Installation factor
Parameter overview with brief description
Parameter
Description
Selection/
User entry
Factory setting
Installation factor
The factor is multiplied by
the mass flow to correct
sub-optimum installations
0 to 9
1