Proline t-mass A 150 HART
Operation options
Hauser
29
8.2.2
Operating philosophy
The individual parts of the operating menu are assigned to certain user roles. Each user
role contains typical tasks within the device lifecycle.
Menu
User role and tasks
Content/meaning
Language
task-oriented
Role "Operator", "Maintenance"
Tasks during operation:
• Configuring the measured value display
• Reading measured values
Defining the operating language
Display/operat.
Configuration of the measured value display (e.g.
display format, display contrast)
Resetting and controlling totalizers
Setup
"Maintenance" role
Commissioning:
• Configuration of the measurement
• Configuration of the outputs
Wizards for quick commissioning:
• Defining the medium
• Configuring the outputs
• Configuring the measured value display
• Defining the output conditioning
• Configuring the low flow cut off
"Advanced setup" submenu:
• For more customized configuration of the
measurement (adaptation to special measuring
conditions)
• Configuration of totalizers
Diagnosis
"Maintenance" role
Fault elimination:
• Diagnostics and elimination of process and
device errors
• Measured value simulation
Contains all parameters for error detection and
analyzing process and device errors:
•
"Diagnostic list" submenu
Contains up to 5 currently pending diagnostic
messages.
•
"Event logbook" submenu
Contains up to 20 or 100 (order option) event
messages that have occurred.
•
"Device information" submenu
Contains information for identifying the device.
•
"Measured values" submenu
Contains all current measured values.
•
"Data logging" submenu (order option)
Storage and visualization of up to 1000 measured
values
•
"Simulation" submenu
Is used to simulate measured values or output values.
•
"Device reset" submenu
Resets the device configuration to certain settings
Expert
function-oriented Tasks that require detailed knowledge of the
function of the device:
• Commissioning measurements under difficult
conditions
• Optimal adaptation of the measurement to
difficult conditions
• Detailed configuration of the communication
interface
• Error diagnostics in difficult cases
Contains all the parameters of the device and makes it
possible to access these parameters directly using an
access code. The structure of this menu is based on the
function blocks of the device:
•
"System" submenu
Contains all higher-order device parameters that do
not pertain either to measurement or the measured
value communication.
•
"Sensor" submenu
Contains all parameters for configuring the
measurement.
•
"Output" submenu
Contains all parameters for configuring the analog
current outputs.
•
"Communication" submenu
Contains all parameters for configuring the digital
communication interface.
•
"Application" submenu
Contains all parameters for configuring the functions
that go beyond the actual measurement (e.g.
totalizer).
•
"Diagnostics" submenu
Contains all parameters for error detection and
analyzing process and device errors and for device
simulation.