Installation
Proline t-mass 65 PROFIBUS DP/PA
26
Hauser
Installation in control panel
1.
Prepare the opening in the panel as illustrated in the diagram.
2.
Slide the housing into the opening in the panel from the front.
3.
Screw the fasteners onto the wall-mount housing.
4.
Screw threaded rods into holders and tighten
until the housing is solidly seated on the panel wall. Afterwards, tighten the locking
nuts.
Additional support is not necessary.
A0001131
Fig. 19:
Engineering unit mm (in)
Pipe mounting
The assembly should be performed by following the instructions in the diagram.
"
Caution!
If a warm pipe is used for installation, make sure
that the housing temperature does not exceed the max. permitted value of +60 °C (+140 °F).
A0001132
Fig. 20:
Engineering unit mm (in)
245 (9.65)
~110 (~4.33)
210 (8.27)
+0.5 (+0.019)
–0.5 (–0.019)
+0.5 (+0.019)
–0.5 (–0.019)
Ø 20…70
(Ø 0.79…2.75)
~
~ 6.1)
155 (
Summary of Contents for Proline t-mass 65 PROFIBUS DA