Proline Prosonic Flow P
Installation
Hauser
13
1
2
15 × DN
3 × DN
15 × DN
3 × DN
3
4
15 × DN
3 × DN
5
6
15 × DN
3 × DN
a
b
20 × DN
3 × DN
20 × DN
3 × DN
A0042041
3
Minimum inlet and outlet runs with various flow obstructions
1
Pipe bend
2
Two pipe bends (on one plane)
3
Two pipe bends (on two planes)
4a reduction
4b Expansion
5
Control valve (2/3 open)
6
Pump
5.1.2
Environment and process requirements
Ambient temperature range
For detailed information on the ambient temperature range, see the Operating
Instructions for the device.
If operating outdoors:
• Install the measuring device in a shady location.
• Avoid direct sunlight, particularly in warm climatic regions.
• Avoid direct exposure to weather conditions.
Temperature tables
For detailed information on the temperature tables, see the separate document entitled
"Safety Instructions" (XA) for the device.