10.2.3 Selecting and setting the medium
The
Medium selection
submenu contains parameters that have to be configured for
selecting and setting the medium.
Navigation
"Setup" menu → Select medium
Select medium
→
Select medium
Select gas type
Reference sound velocity
Temperature coefficient sound velocity
Pressure compensation
Pressure value
External pressure
Parameter overview with brief description
Parameter
Prerequsite
Description
Selection / User
entry / User
interface
Factory setting
Select medium
–
Select medium type.
Gas
Liquid
Select gas type
The following option is
selected in the
Medium
selection
parameter:
Gas
Select measured gas type.
Gas type choose list
Methane CH4
Reference sound velocity
The following option is
selected in the
Select gas type
parameter:
Others
Enter sound velocity of gas at 0
°C (32 °F).
1 to
99
999.9999 m/s
0 m/s
Temperature coefficient sound
velocity
The following option is
selected in the
Select gas type
parameter:
Others
Enter temperature coefficient
for the gas sound velocity.
Positive floating-
point number
0 (m/s)/K
Pressure compensation
The following option is
selected in the
Medium
selection
parameter:
Gas
Select pressure compensation
type.
• Off
• Fixed value
• External value
Off
Pressure value
The following option is
selected in the
Pressure
compensation
parameter:
Fixed value
Enter process pressure to be
used for pressure correction.
Positive floating-
point number
0 bar
External pressure
The following option is
selected in the
Pressure
compensation
parameter:
External value
Positive floating-
point number
0 bar