Brief Operating Instructions

Proline Promass E 200

Coriolis flowmeter

These Instructions are Brief Operating Instructions; they are

not a substitute for the Operating Instructions pertaining to

the device.
Detailed information about the device can be found in the

Operating Instructions and the other documentation:

• On the CD-ROM supplied (is not included in the delivery for

all device versions).

• Available for all device versions via:

– Internet: 

www.endress.com/deviceviewer

– Smart phone/tablet: 

Hauser Operations App

Description of the procedure (→   10)

KA00050D/06/EN/16.14

71241802

Summary of Contents for Proline Promass E 200

Page 1: ...ons pertaining to the device Detailed information about the device can be found in the Operating Instructions and the other documentation On the CD ROM supplied is not included in the delivery for all...

Page 2: ...conditions 14 6 2 Mounting the measuring device 19 6 3 Post installation check 21 7 Electrical connection 22 7 1 Connection conditions 22 7 2 Connecting the measuring device 28 7 3 Hardware settings...

Page 3: ...rical symbols Symbol Meaning A0011197 Direct current A terminal to which DC voltage is applied or through which direct current flows A0011198 Alternating current A terminal to which alternating voltag...

Page 4: ...83 Preferred Indicates procedures processes or actions that are preferred A0011184 Forbidden Indicates procedures processes or actions that are forbidden A0011193 Tip Indicates additional information...

Page 5: ...instructions in the Operating Instructions and supplementary documentation as well as in the certificates depending on the application Following instructions and basic conditions 2 2 Designated use A...

Page 6: ...ss Hauser is glad to provide assistance in verifying the corrosion resistance of fluid wetted materials but does not accept any warranty or liability as minute changes in the temperature concentration...

Page 7: ...ndition in which it is safe to operate It meets general safety standards and legal requirements It also complies with the EC directives listed in the device specific EC Declaration of Conformity Endre...

Page 8: ...4 5 6 7 8 9 E A0014056 1 Important components of a measuring device 1 Electronics compartment cover 2 Display module 3 Main electronics module 4 Cable glands 5 Transmitter housing incl HistoROM 6 I O...

Page 9: ...0015502 A0013699 Do the nameplate data match the ordering information on the delivery note A0015502 A0013697 Is the CD ROM with the Technical Documentation depends on device version and documents pres...

Page 10: ...er no 1 2 3 4 A0021952 2 Example of a nameplate 1 Order code 2 Serial number Ser no 3 Extended order code Ext ord cd 4 2 D matrix code QR code For detailed information on the breakdown of the specific...

Page 11: ...ble both for android smart phones Google Play store and for iPhones and iPads App Store Via the serial number 1 Launch the Endress Hauser Operations App 2 Enter the serial number Ser no of the device...

Page 12: ...g or slipping Observe the weight specified on the packaging stick on label Observe the transport instructions on the stick on label on the electronics compartment cover A0015606 Observe the following...

Page 13: ...Proline Promass E 200 Storage and transport Endress Hauser 13 A0015605...

Page 14: ...by the construction of the device 6 1 1 Mounting position Mounting location A0015595 Installation in down pipes However the following installation suggestion allows for installation in an open vertic...

Page 15: ...4 5 A0015596 3 Installation in a down pipe e g for batching applications 1 Supply tank 2 Sensor 3 Orifice plate pipe restriction 4 Valve 5 Batching tank DN orifice plate pipe restriction mm in mm in...

Page 16: ...tion C Horizontal orientation transmitter head down A0015590 2 Exception D Horizontal orientation transmitter head at side A0015592 1 Applications with low process temperatures may reduce the ambient...

Page 17: ...range Measuring device 40 to 60 C 40 to 140 F Local display 20 to 60 C 4 to 140 F The readability of the display may be impaired at temperatures outside the temperature range If operating outdoors Av...

Page 18: ...ns Electrical heating e g with electric band heaters Via pipes carrying hot water or steam Via heating jackets For detailed information about heating with electrical band heaters refer to the Operatin...

Page 19: ...point adjustment is advisable only in special cases To achieve maximum measuring accuracy even with low flow rates Under extreme process or operating conditions e g very high process temperatures or...

Page 20: ...e gaskets are clean and undamaged Install the gaskets correctly 1 Ensure that the direction of the arrow on the nameplate of the sensor matches the flow direction of the fluid 2 Install the measuring...

Page 21: ...on document on the CD ROM provided Ambient temperature 17 Measuring range Has the correct orientation for the sensor been selected According to sensor type According to medium temperature According to...

Page 22: ...s provided by the customer must fulfill the following requirements Electrical safety In accordance with applicable federal national regulations Permitted temperature range 40 C 40 F to 80 C 176 F Mini...

Page 23: ...20 1 5 with cable 6 to 12 mm 0 24 to 0 47 in Plug in spring terminals for device version without integrated overvoltage protection wire cross sections 0 5 to 2 5 mm2 20 to 14 AWG Screw terminals for d...

Page 24: ...ission Ground terminal for cable shield Order code for Output Terminal numbers Output 1 Output 2 1 2 3 4 Option A 4 20 mA HART passive Option B 1 4 20 mA HART passive Pulse frequency switch output pas...

Page 25: ...n the feed side Experience shows that the best results with regard to EMC are achieved in most cases in installations with one sided shielding on the feed side without capacitance termination at the f...

Page 26: ...tential equalization the multiple grounding of the cable shield causes mains frequency equalizing currents Damage to the bus cable shield Only ground the bus cable shield to either the local ground or...

Page 27: ...V DC 32 V 1 External supply voltage of the power supply unit with load 2 For device versions with SD03 local display The terminal voltage must be increased by DC 2 V if backlighting is used 3 For dev...

Page 28: ...1 Remove dummy plug if present 2 NOTICE Insufficient sealing of the housing Operational reliability of the measuring device could be compromised Use suitable cable glands corresponding to the degree...

Page 29: ...mm in 20mm 3 mm A0013836 Connect the cable in accordance with the terminal assignment For HART communication When connecting the cable shielding to the ground terminal observe the grounding concept o...

Page 30: ...the device is not recognized by the master All measuring devices are delivered from the factory with the device address 126 and with the software addressing method 2 9 8 3 4 5 6 7 8 1 D IP O N A00156...

Page 31: ...ch 8 is set to the ON position the address is defined in the operating menu Setup menu Communication submenu Device address parameter 7 4 Ensuring the degree of protection The measuring device fulfill...

Page 32: ...s installed firmly tightened and leak tight Cable run with water trap 31 Depending on the device version are all the device plugs firmly tightened 28 Does the supply voltage match the specifications o...

Page 33: ...enu for operators and maintenances Operator Maintenance task oriented function oriente d Expert A0014058 EN 8 Schematic structure of the operating menu 8 1 2 Operating philosophy The individual parts...

Page 34: ...channel number symbol for diagnostic behavior 1 4 Status area 1 5 Measured value 1 6 Unit for the measured value 1 7 Operating elements 2 Operational display with measured value shown as 1 bar graph...

Page 35: ...rence density A0013947 Temperature A0013943 Totalizer The measurement channel number indicates which of the three totalizers is displayed A0013945 Output The measurement channel number indicates which...

Page 36: ...A0013967 A0013968 A0013972 A0013963 Submenu Wizard Parameters within a wizard Parameter locked 8 2 3 Editing view Input mask Operating symbols in the numeric editor A0013985 A0016621 A0013986 Confirms...

Page 37: ...s the selection bar downwards in a choose list With a Wizard Confirms the parameter value and goes to the next parameter With a text and numeric editor Moves the selection bar to the right forwards in...

Page 38: ...the keys simultaneously Reduces the contrast brighter setting A0013954 Plus Enter key combination press and hold down the keys simultaneously Increases the contrast darker setting A0013955 Minus Plus...

Page 39: ...is indicated by the Access status display parameter Navigation path Operation Access status display 8 2 7 Disabling write protection via access code If the symbol appears on the local display in fron...

Page 40: ...Switching on the keypad lock The keypad lock is switched on automatically Each time the device is restarted If the device has not been operated for longer than one minute in the measured value display...

Page 41: ...rol system e g PLC 2 Transmitter power supply unit e g RN221N with communication resistor 3 Connection for Commubox FXA195 and Field Communicator 475 4 Field Communicator 475 5 Computer with operating...

Page 42: ...3 Computer with FieldCare operating tool with COM DTM CDI Communication FXA291 9 System integration For information on system integration see the Operating Instructions for the device 10 10 Commission...

Page 43: ...with the device 10 3 Setting the operating language Factory setting English or ordered local language XXXX XXX X X 20 50 Operation Setup Main menu 0104 1 Language English Espa ol Fran ais Language En...

Page 44: ...etup menu Device tag Parameter overview with brief description Parameter Description User entry Factory setting Device tag Enter tag for measuring point Max 32 characters such as letters numbers or sp...

Page 45: ...operational display mode from the navigation and editing view If write access is activated via access code it can be also be deactivated only via the access code 39 The user role with which the user...

Page 46: ...Hardware locked option is displayed in the Locking status parameter In addition on the local display the symbol appears in front of the parameters in the header of the operational display and in the n...

Page 47: ...age A0013940 EN 11 Message for remedial measures 1 Diagnostic information 2 Short text 3 Service ID 4 Diagnostic behavior with diagnostic code 5 Operation time of occurrence 6 Remedial measures The us...

Page 48: ...www addresses endress com...