Proline Promag L 400 HART
Commissioning
Hauser
81
Assign current output
Select process variable for
current output.
• Off
• Volume flow
• Conductivity
• Mass flow
Volume flow
Assign pulse output 1-2
Select the process variable for
the pulse output.
• Off
• Volume flow
• Mass flow
Off
Assign frequency output 1-2 Select the process variable for
the frequency output.
• Off
• Volume flow
• Conductivity
• Mass flow
Off
Measuring mode output 1-3 Select the measuring mode
for current output.
• Forward flow
• Forward/reverse flow
• Reverse flow (only for
pulse and frequency
output)
• Reverse flow
compensation
Forward flow
10.4.6 Configuring the low flow cut off
The
Low flow cut off
wizard guides you systematically through all parameters that have to be set
for configuring the low flow cut off.
Navigation path
"Setup" menu
®
Low flow cut off
Sequence of the wizard
Volume flow
Assign variable
Off value
End of wizard
Off
On value
Mass flow
Pres. shock sup.
A0017209-EN
å
29
"Low flow cut off" wizard in the "Setup" menu
Parameter overview with brief description
Parameter
Description
Selection/
User entry
Factory setting
Assign process variable
Select process variable for
low flow cut off.
• Off
• Volume flow
• Mass flow
Volume flow