Installation
Proline Promag L 400 HART
20
Hauser
A0015591
Horizontal
The measuring electrode plane must be horizontal. This prevents brief insulation of the two
measuring electrodes by entrained air bubbles.
With horizontal orientation, empty pipe detection only works if the transmitter housing is
pointing upwards as otherwise there is no guarantee that the empty pipe detection function
will actually respond to a partially filled or empty measuring tube.
A
A
1
2
3
2
A0016260
å
6
Horizontal orientation
1
EPD electrode for empty pipe detection
2
Measuring electrodes for signal detection
3
Reference electrode for potential equalization
Inlet and outlet runs
If possible, install the sensor upstream from fittings such as valves, T-pieces or elbows.
Observe the following inlet and outlet runs to comply with accuracy specifications:
• Inlet run
³
5
´
DN
• Outlet run
³
2
´
DN
5 × DN
³
³
2 × DN
A0016275
Installation dimensions
For the dimensions and installation lengths of the device, see the "Technical Information"
document, "Mechanical construction" section