Pressure tightness
Promag D
Measuring tube: 0 mbar abs (0 psi abs) with a fluid temperature of
60 °C (
140 °F)
Promag L (Measuring tube lining: Polyurethane, Hard rubber)
Promag L
Measuring tube lining: PTFE
Promag W
Promag P
Measuring tube lining: PFA
Promag L
Nominal diameter
Measuring
tube lining
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] ([psi]) at various fluid
temperatures
[mm]
[inch]
25 °C
50 °C
80° C
77 °F
122 °F
176° F
50 to 1200
2 to 48"
Polyurethane
0
0
-
350 to 1200
14 to 48"
Hard rubber
0
0
0
Promag L
Nominal diameter
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] ([psi]) at various fluid temperatures
[mm]
[inch]
25 °C
90 °C
77 °F
194 °F
[mbar]
[psi]
[mbar]
[psi]
50
2"
0
0
0
0
65
-
0
0
40
0.58
80
3"
0
0
40
0.58
100
4"
0
0
135
1.96
125
-
135
1.96
240
3.48
150
6"
135
1.96
240
3.48
200
8"
200
2.90
290
4.21
250
10"
330
4.79
400
5.80
300
12"
400
5.80
500
7.25
Promag W
Nominal diameter
Measuring
tube lining
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] ([psi]) at various fluid temperatures
[mm]
[inch]
25 °C
50 °C
80° C
100 °C
130 °C
150 °C
180 °C
77 °F
122 °F
176° F
212 °F
266 °F
302 °F
356 °F
25 to 1200 1 to 48" Polyurethane
0
0
-
-
-
-
-
50 to 2000 2 to 78" Hard rubber
0
0
0
-
-
-
-
Promag P
Nominal diameter
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] ([psi]) at various fluid temperatures
[mm]
[inch]
25 °C
80° C
100 °C
130 °C
150 °C
180 °C
77 °F
176° F
212 °F
266 °F
302 °F
356 °F
25
1"
0
0
0
0
0
0
32
-
0
0
0
0
0
0
40
1 ½"
0
0
0
0
0
0
50
2"
0
0
0
0
0
0
65
-
0
*
0
0
0
0
80
3"
0
*
0
0
0
0