Tankside Monitor NRF81
Operating menu
Hauser
175
"Temperature" submenu
Read access
Maintenance
Navigation
Setup → Advanced setup → Application → Tank configuration
→ Temperature
Liquid temp source
Navigation
Setup → Advanced setup → Application → Tank configuration → Temperature
→ Liquid temp source
Description
Defines source from which the liquid temperature is obtained.
Selection
• Manual value
• HART device 1 ... 15 temperature
• AIO B1-3 value
• AIO C1-3 value
• AIP B4-8 value
• AIP C4-8 value
Factory setting
Manual value
Additional information
Read access
Operator
Write access
Maintenance
Manual liquid temperature
Navigation
Setup → Advanced setup → Application → Tank configuration → Temperature
→ Manual liquid temperature
Prerequisite
Manual value
Description
Defines the manual value of the liquid temperature.
User entry
–50 to 300 °C
Factory setting
25 °C
Additional information
Read access
Operator
Write access
Maintenance