MMP20 SONO-DIS (option D)
Page 12
Hauser
Meaning of displayed text:
Text (English)
Meaning
Density
Raw density value of the measured fresh concrete
Water content:
Kiln-dry water content in l/m
3
EC-TRIME
Electrical Conductivity - electrical conductivity
based on the TDR radar signal and therefore an
assessment of the cement in the concrete mix.
Serial No.:
Serial number of the probe or SONO-DIS
HW:
Hardware version
FW:
Firmware version
Switching on the SONO-DIS handheld device
Press and hold the
key for about 1 second to switch on the SONO-DIS.
The SONO-DIS attempts to communicate with the connected probe during the power-up process.
This takes around 4 seconds. If no probe is connected or if the probe cannot be found for some other
reason, an error message appears on the screen.
If the SONO-DIS managed to successfully find the probe, the measurement background appears on
the screen depending on the specific operating mode. The message "Calibrating" appears on the
bottom of the display during the power-up process. This means that the SONO-DIS is adjusting itself
to the SONO-WZ probe. After this, the SONO-DIS is ready for operation.
Note:
If it is not possible to connect to the probe even after several attempts, check whether the
probe is connected correctly. If this does not rectify the problem, please contact our
Service Department.
Switching off the SONO-DIS handheld device
To switch off the SONO-DIS handheld device, press and hold the
key for approximately 1 second.