Operating menu
Micropilot FMR20 HART
76
Hauser
15.3 "Setup" menu
•
: Indicates navigation to the parameter via operating tools
•
: Indicates parameters that can be locked via the access code.
Navigation
Setup
Device tag
Navigation
Setup → Device tag
Description
Enter a unique name for the measuring point to identify the device quickly within the
plant.
User entry
Character string comprising numbers, letters and special characters (#32)
Factory setting
EH_FMR20_####### (last 7 digits of the device serial number)
Distance unit
Navigation
Setup → Distance unit
Description
Used for the basic calibration (Empty / Full).
Selection
SI units
m
US units
ft
Empty calibration
Navigation
Setup → Empty calibr.
Description
Distance between process connection and minimum level (0%).
User entry
0.0 to 20 m
Factory setting
Depends on the antenna version
Full calibration
Navigation
Setup → Full calibr.
Description
Distance between minimum level (0%) and maximum level (100%).