
Installation
Micropilot FMR20 HART
14
Hauser
5
Installation
5.1
Installation conditions
5.1.1
Installation types
B
C
D
A
F
E
A0045309
3
Wall, ceiling or nozzle installation
A
Wall or ceiling mounting, adjustable
B
Mounted at rear thread
C
Horizontal installation in cramped spaces
D
Ceiling installation with counter nut (included in delivery)
E
Installation with adjustable flange seal
F
Installation with FAU40 alignment unit
Caution!
• The sensor cables are not designed as supporting cables. Do not use them for
suspension purposes.
• Always operate the device in a vertical position in free-space applications.
5.1.2
Nozzle installation
The antenna should project out of the nozzle for optimum measurement. The interior of
the nozzle must be smooth and may not contain any edges or welded joints. The edge of
the nozzle should be rounded if possible.