Technical data
Liquistation CSF39
182
Hauser
Supply voltage
Depending on version:
• 100 to 120/200 to 240 V AC ±10 %, 50/60 Hz
• 24 V DC +15/
‐
9 %
Cable entries
Depending on version:
• 1 x M25, 7 x M20 cable gland
• 1 x M25, 1 x M20 cable gland
Permitted cable diameter:
• M20x1.5 mm: 7 to 13 mm (0.28 to 0.51")
• M25x1.5 mm: 9 to 17 mm (0.20 to 0.67")
Mains fuse
• T3.15A (for 230V power supply)
• T10A (for 24V power supply)
• For version with cCSAus approval: T4A (for cooling module)
Power consumption
• Version with vacuum pump: 290 VA
• Version with peristaltic pump: 290 VA
Power failure
Power supply (optional): 2 x 12 V, 7.2 Ah, with additional charge controller
Replace the rechargeable batteries with type Panasonic LC-R127R2PG1.
Real-time clock: lithium battery, type CR2032
15.10 Performance characteristics
Sampling methods
Vacuum pump:
• Time-paced
• In proportion to volume
Peristaltic pump:
• Time-paced
• In proportion to volume
• Flow proportional sampling/time override (CTVV)
Dosing volume
Vacuum pump:
20 to 350 ml (0.7 to 12 fl.oz.)
Peristaltic pump:
10 to 10000 ml (0.3 to 340 fl.oz.)
The dosing accuracy and the repeatability of a sample volume < 20 ml can vary,
depending on the specific application.
Dosing accuracy
•
Vacuum pump:
± 5 ml (0.17 fl.oz.) or 5 % of the set volume
•
Peristaltic pump:
± 5 ml (0.17 fl.oz.) or 5 % of the set volume
Repeatability
5 %
Intake speed
> 0.5 m/s (> 1.6 ft/s) for ≤ 13 mm (1/2") ID, as per EN 25667, ISO 5667, CEN 16479-1