Incoming acceptance and product identification
Indumax CLS54
8
Hauser
Temperature classes
Temperature class Ambient temperature range T
a
Medium temperature range T
med
T6
-20 °C to +60 °C
-10 °C ≤ T
med
≤ + 55 °C
T4
-10 °C ≤ T
med
≤ + 105 °C
T3
-10 °C ≤ T
med
≤ + 125 °C
1)
1)
150 °C for maximum 60 min
Sensors with CSA approval (CLS504-O******)
Observe the documentation and the control drawings of the transmitter.
3
Incoming acceptance and product identification
3.1
Incoming acceptance
1. Verify that the packaging is undamaged.
Notify your supplier of any damage to the packaging.
Keep the damaged packaging until the matter has been settled.
2. Verify that the contents are undamaged.
Notify your supplier of any damage to the delivery contents.
Keep the damaged products until the matter has been settled.
3. Check the delivery for completeness.
Check it against the delivery papers and your order.
4. Pack the product for storage and transportation in such a way that it is protected
against impact and moisture.
The original packaging offers the best protection.
The permitted ambient conditions must be observed (see "Technical data").
If you have any questions, please contact your supplier or your local sales center.
3.2
Scope of delivery
The scope of delivery includes:
• Sensor in the version ordered
• Operating Instructions