Technical data
Proline Promag P 500 HART
192
Hauser
Nominal diameter
ASME
[mm]
[in]
Pressure rating
[lbs]
100
4
Class 150
30.9
150
6
Class 150
51.8
200
8
Class 150
94.8
250
10
Class 150
161.0
300
12
Class 150
238.1
350
14
Class 150
381.5
400
16
Class 150
447.6
450
18
Class 150
557.9
500
20
Class 150
624.0
600
24
Class 150
888.6
Measuring tube
specification
Nominal
diameter
Pressure rating
Process connection internal diameter
EN
(DIN)
ASME
AS 2129 AS 4087
JIS
PFA
PTFE
[mm]
[in]
[bar]
[psi]
[bar]
[bar]
[bar]
[mm]
[in]
[mm]
[in]
15
½
PN 40 Class 150
–
–
20K
–
–
15
0.59
25
1
PN 40 Class 150 Table E
–
20K
23
0.91
26
1.02
32
–
PN 40
–
–
–
20K
32
1.26
35
1.38
40
1 ½
PN 40 Class 150
–
–
20K
36
1.42
41
1.61
50
2
PN 40 Class 150 Table E
PN 16
10K
48
1.89
52
2.05
65
–
PN 16
–
–
–
10K
63
2.48
67
2.64
80
3
PN 16 Class 150
–
–
10K
75
2.95
80
3.15
100
4
PN 16 Class 150
–
–
10K
101
3.98
104
4.09
125
–
PN 16
–
–
–
10K
126
4.96
129
5.08
150
6
PN 16 Class 150
–
–
10K
154
6.06
156
6.14
200
8
PN 10 Class 150
–
–
10K
201
7.91
202
7.95
250
10
PN 10 Class 150
–
–
10K
–
–
256
10.1
300
12
PN 10 Class 150
–
–
10K
–
–
306
12.0
350
14
PN 10 Class 150
–
–
10K
–
–
337
13.3
400
16
PN 10 Class 150
–
–
10K
–
–
387
15.2
450
18
PN 10 Class 150
–
–
10K
–
–
432
17.0
500
20
PN 10 Class 150
–
–
10K
–
–
487
19.2
600
24
PN 10 Class 150
–
–
10K
–
–
593
23.3
Materials
Transmitter housing
Proline 500 – digital transmitter housing
Order code for "Transmitter housing":
• Option
A
"Aluminum coated": aluminum, AlSi10Mg, coated
• Option
D
"Polycarbonate": polycarbonate
Summary of Contents for Hart Proline Promag P 500