Proline Promag P 500 HART
Technical data
Hauser
177
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.3/10 m/s)
Full scale value current
output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
[mm]
[in]
[dm
3
/min]
[dm
3
/min]
[dm
3
]
[dm
3
/min]
80
3
90 to 3
000
750
5
12
100
4
145 to 4
700
1200
10
20
125
–
220 to 7
500
1850
15
30
150
6
20 to 600 m
3
/h
150 m
3
/h
0.03 m
3
2.5 m
3
/h
200
8
35 to 1
100 m
3
/h
300 m
3
/h
0.05 m
3
5 m
3
/h
250
10
55 to 1
700 m
3
/h
500 m
3
/h
0.05 m
3
7.5 m
3
/h
300
12
80 to 2
400 m
3
/h
750 m
3
/h
0.1 m
3
10 m
3
/h
350
14
110 to 3
300 m
3
/h
1
000 m
3
/h
0.1 m
3
15 m
3
/h
400
16
140 to 4
200 m
3
/h
1
200 m
3
/h
0.15 m
3
20 m
3
/h
450
18
180 to 5
400 m
3
/h
1
500 m
3
/h
0.25 m
3
25 m
3
/h
500
20
220 to 6
600 m
3
/h
2
000 m
3
/h
0.25 m
3
30 m
3
/h
600
24
310 to 9
600 m
3
/h
2
500 m
3
/h
0.3 m
3
40 m
3
/h
Flow characteristic values in US units
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.3/10 m/s)
Full scale value current
output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
[in]
[mm]
[gal/min]
[gal/min]
[gal]
[gal/min]
½
15
1.0 to 27
6
0.1
0.15
1
25
2.5 to 80
18
0.2
0.25
1 ½
40
7 to 190
50
0.5
0.75
2
50
10 to 300
75
0.5
1.25
3
80
24 to 800
200
2
2.5
4
100
40 to 1
250
300
2
4
6
150
90 to 2
650
600
5
12
8
200
155 to 4
850
1200
10
15
10
250
250 to 7
500
1500
15
30
12
300
350 to 10
600
2400
25
45
14
350
500 to 15
000
3600
30
60
16
400
600 to 19
000
4800
50
60
18
450
800 to 24
000
6000
50
90
20
500
1
000 to 30
000
7500
75
120
24
600
1
400 to 44
000
10500
100
180
Recommended measuring range
Operable flow range
Over 1000 : 1
Summary of Contents for Hart Proline Promag P 500
Page 210: ...www addresses endress com ...