Cerabar S/Deltabar S/Deltapilot S 4...20mA HART
Description of parameters
Hauser
67
Table 10: (GROUP SELECTION
) OPERATING MENU
SETTINGS
BASIC SETUP "Level"
Parameter name
Description
Prerequisite
:
• MEASURING MODE = level (
Note:
See also
– Page 70 ff, Tables 11 to 13: BASIC SETUP – contd.
– Page 96 ff, Table 16: EXTENDED SETUP
– Page 100 ff, Table 18: LINEARISATION – on-site operation
– Page 104 ff, Table 19: LINEARISATION – Digital communication
– Page 122 ff, Table 28: PROCESS VALUES
– Page 14 ff, Section 5 "Level measurement".
MEASURING MODE
Selection
Select the measuring mode.
The operating menu is structured according to the selected measuring mode.
#
Warning!
If the measuring mode is changed, the span setting (URV) must be verified in the
"Calibration"
"Basic Setup" operating menu and, if necessary, reconfigured.
Prerequisite:
• Digital communication
Options
:
• Pressure
• Level
• Deltabar S: Flow
Factory setting:
Pressure
PRESS. ENG. UNIT (060)
Selection
Select pressure unit.
If a new pressure unit is selected, all pressure-specific parameters are converted and
displayed with the new unit.
Options:
• mbar, bar
• mmH2O, mH2O, inH2O, ftH2O
1)
• Pa, hPa, kPa, MPa
• psi
• mmHg, inHg
2)
• Torr
• g/cm
2
, kg/cm
2
• lb/ft
2
• atm
• gf/cm
2
, kgf/cm
2
• User unit,
See also the following parameter description for CUSTOMER UNIT P and
CUST. UNIT FACT. P.
1) The conversion factor of the pressure units refers to a reference temperature of 4 °C
(39.2 °F).
2) The conversion factor of the pressure units refers to a reference temperature of 0 °C
(32 °F).
Factory setting:
Depends on the sensor nominal measuring range mbar or bar or as per order
specifications