background image

 TI415P/00/en

Technical Information

Cerabar T PMC131, PMP131, PMP135

Pressure Transducer
With ceramic and metal sensors
For absolute pressure and gauge pressure measurement up to 400 bar
Extremely stable, overload-resistant and reliable

Application

Cerabar T is a pressure transducer for measuring absolute 
pressure and gauge pressure in gases, vapors, liquids and 
dusts. 
Hygienic and threaded connections are available as 
process connections.

Your benefits

This compact pressure transducer impresses with its 
well-engineered construction:

• High reproducibility and long-term stability.
• Finely graduated measuring ranges from vacuum up to

400 bar/6000 psi.

• Ceraphire

®

 ceramic sensor: corrosion-proof, abrasion-

proof and extremely overload-resistant.

• Deployed for pressure monitoring up to SIL 2 as per 

IEC 61508/IEC 61511-1

• Sensors

– Dry capacitance ceramic sensor (Ceraphire

®

) for 

measuring ranges up to 40 bar:
overload-resistant, vacuum-proof, stable against 
alternating load

– Piezoresistive sensor with metal diaphragm for 

measuring ranges up to 400 bar

Summary of Contents for Cerabar T PMC131

Page 1: ...process connections Your benefits This compact pressure transducer impresses with its well engineered construction High reproducibility and long term stability Finely graduated measuring ranges from v...

Page 2: ...nvironment 10 Ambient temperature range 10 Storage temperature range 10 Climate class 10 Degree of protection 10 Vibration resistance 10 Electromagnetic compatibility 10 Operating conditions process 1...

Page 3: ...mparator with an adjustable hysteresis compares this signal with the pre set switch point and then activates the transistor output Cerabar T PMC131 PMP131 PMP135 P01 PMC131xx 14 xx xx xx 000 P01 PMP13...

Page 4: ...riable Absolute pressure or gauge pressure Measuring range up to 400 bar 6000 psi see Page 18 Ordering information section Output Analog output PMC131 PMP131 PMP135 Output signal 4 to 20 mA Load PMC13...

Page 5: ...er supply PMC131 Plug cable connection P01 PMC131xx 04 xx xx xx 001 Electrical connection Analog current output P01 PMC131xx 04 xx xx xx 002 1 Plug M 16 x 1 5 DIN 43650 A NPT 2 Plug M 12 x 1 3 Cable r...

Page 6: ...ical connection provided by customer use only shielded cable Plug M 16 x 1 5 DIN 43650 A NPT Plug DIN 43650 C Plug M 12x1 5 m cable only analog output Plug in housing Coupling nut Reference pressure l...

Page 7: ...l connection provided by customer use only shielded cable Supply voltage PMC131 11 to 30 V DC PMP131 and PMP135 current output 2 wire version For non hazardous areas 12 to 30 V DC Ex i no load voltage...

Page 8: ...Non reproducibility 0 5 of URL Rise time T90 PMC131 20 ms Settling time PMP131 and PMP135 2 to 5 ms 1 extended specifications apply to customer specific measuring ranges Example PMC131 version A1R No...

Page 9: ...f URL 10 K Nominal value 6 bar by 0 1 of URL 10 K higher Output signal typically 0 2 of URL 10 K max 0 5 of URL 10 K PMP131 and PMP135 switch output Switch point typically 0 2 of URL 10 K max 0 5 of U...

Page 10: ...x1 IP 65 NEMA 4 Cable IP 68 NEMA 6P 1 mWS 24 h PMP131 and PMP135 Plug M 16 x 1 5 DIN 43650 A NPT IP 65 NEMA 4X Plug M 12x1 and gauge pressure sensors IP 65 NEMA 4X Plug M 12x1 and absolute pressure se...

Page 11: ...80 inH2O 500 mbarabs Versions D12 D38 W6O S4N with URV 20 mbar or 100 mbar 1 5 psi 15 inH2O or 30 inH2O 700 mbarabs Versions D10 D3W D31 Q4D V6F W6N W6R PMP131 and PMP135 10 mbarabs Pressure specific...

Page 12: ...r the height of process connection A Process connections P01 PMC131xx 06 xx xx xx 002 Process connections PMC131 Material AISI 304 1 4301 1 Version 1 Thread ISO 228 G 2 Version 2 Thread ANSI MNPT FNPT...

Page 13: ...Plug M 12 IP 65 See the following figure for the dimensions of process connection A PMP131 Process connections P01 PMP131xx 06 xx xx xx 002 Process connections PMP131 Material AISI 304 1 4301 1 Versi...

Page 14: ...ontact with the medium Ra 0 8 m M Diaphragm diameter 17 2 mm 1 Version F Clamp ISO 2852 or DN 22 DIN 32676 3A 2 Version G Tri Clamp 1 to 1 ISO 2852 or DN 25 to DN 40 DIN 32676 3A 3 Version H Tri Clamp...

Page 15: ...ctrical connection Plug M12 Polyamide PA Valve connector Sheathing made of polyamide PA Cable Sheathing made of polyurethane PUR UL94 V0 UV resistant Operating elements Operating elements Position of...

Page 16: ...URL 2 Switch point adjustment 0 to 100 of URL Factory setting 50 of URL 3 LED color code for checking the switch status green off red on 4 Connect voltmeter to test pins 0 to 1 V corresponds to 0 to 1...

Page 17: ...aries or operating materials derived from animals are used in production or processing Process wetted device components are listed in the Mechanical construction and Ordering information sections Stan...

Page 18: ...1 6 bar 0 to 160 kPa 12 bar 2 bar 18 bar 1 8 MPa A1K 0 to 2 bar 0 to 200 kPa 12 bar 2 bar 18 bar 1 8 MPa A1Q 0 to 4 bar 0 to 400 kPa 16 7 bar 4 bar 25 bar 2 5 MPa A1R 1 0 to 6 bar 0 to 600 kPa 26 7 ba...

Page 19: ...0 psi 3 psi 75 psi Sensors for absolute pressure A2G 0 to 1 bar 0 to 100 kPa 6 7 bar 1 bar 10 bar 1 MPa A2H 1 0 to 1 6 bar 0 to 160 kPa 12 bar 2 bar 18 bar 1 8 MPa A2K 0 to 2 bar 0 to 200 kPa 12 bar 2...

Page 20: ...nal inspection report 50 Sensor range MWP OPL Sensor range MWP maximum working pressure OPL over pressure limit Sensors for gauge pressure A1G 0 to 1 bar 0 to 100 kPa 2 7 bar 4 bar 400 kPa A1H 0 to 1...

Page 21: ...W 0 to 25 bar 0 to 2 5 MPa 25 bar 100 bar 10 MPa A2X 0 to 40 bar 0 to 4 MPa 60 bar 160 bar 16 MPa A2Z 0 to 60 bar 0 to 6 MPa 60 bar 240 bar 24 MPa B70 0 to 100 bar 0 to 10 MPa 100 bar 400 bar 40 MPa B...

Page 22: ...to 1 bar 0 to 100 kPa 2 7 bar 4 bar 400 kPa A1H 0 to 1 6 bar 0 to 160 kPa 4 bar 6 4 bar 640 kPa A1N 0 to 2 5 bar 0 to 250 kPa 6 7 bar 10 bar 1 MPa A1Q 0 to 4 bar 0 to 400 kPa 10 7 bar 16 bar 1 6 MPa...

Page 23: ...version N Material AISI 316L 1 4435 Gasket enclosed silicone O ring Order number 52001051 Optional with inspection certificate 3 1 Order number 52011896 P01 PMP13xxx 00 xx 00 xx 005 60 0 4 0 02 2 4 2...

Page 24: ...Cerabar T PMP131 PMP135 SD160P 00 en Safety Instructions Cerabar T PMC131 ATEX II 3 G EEx nA II T4 XA191P 00 a3 Cerabar T PMP131 ATEX II 1 2 G or 2 G EEx ib IIC T6 XA142P 00 a3 ATEX II 3 G EEx nA II T...