Cerabar M
Hauser
67
Ordering information
PMC41
This overview does not identify options which are mutually exclusive.
10
Approval:
R
For non-hazardous areas
G
ATEX II 1/2 G
EEx ia IIC T6
F
ATEX II 1 G
EEx ia IIC T6
H
ATEX II 2 G
EEx ia IIC T6
N
ATEX II 3 G
EEx nA II T5
J
ATEX II 1/2 G 1/2 D
EEx ia IIC T6
K
ATEX II 1/2 D
EEx ia IIC T6
L
ATEX II 1/3 D
C
CSA
General Purpose
S
CSA
IS, Class I, II, III Division 1, Groups A - G
T
CSA
Class II, III, Division 1, Groups E – G (Dust Ex), Class I, Division 2, Groups A – D
P
FM
IS, Class I, II, III, Division 1, Groups A – G
M
FM
DIP, Class II, III Division 1, Groups E – G
D
IECEx
Zone 1 Ex ia IIC T6
U
NEPSI
Ex ia IIC T6
Y
Special version, to be specified
20
Housing; Electrical connection:
E1
316L; gland M20, IP 66
C1
316L; thread NPT 1/2, IP 66
G1
316L; thread G 1/2, IP 66
H1
316L; plug Han7D, IP 65
L1
316L; plug M12, IP 66 (in conjunction with absolute pressure sensors IP 68/NEMA 6P)
K1
316L; cable 5 m, IP 68 + atmospheric pressure compensation
E2
Alu; gland M20, IP 66
C2
Alu; thread NPT 1/2, IP 66
G2
Alu; thread G 1/2, IP 66
H2
Alu; plug Han7D, IP 65
L2
Alu; plug M12, IP 66 (in conjunction with absolute pressure sensors IP 68/NEMA 6P)
K2
Alu; cable 5 m, IP 68 + atmospheric pressure compensation
V2
Alu; valve plug M16 ISO4400, IP64
Y9
Special version, to be specified
30
Sensor range; MWP; OPL:
Sensor range
MWP (maximum working
pressure)
OPL (overpressure limit)
Sensors for overpressure
1C
0 to 100 mbar/10 kPa/1.5 psi
2.7 bar/270 kPa/40 psi
4 bar/400 kPa/60 psi
1F
0 to 400 mbar/40 kPa/6 psi
5.3 bar/530 kPa/80 psi
8 bar/800 kPa/120 psi
1H
0 to 1 bar/100 kPa/15 psi
6.7 bar/670 kPa/100 psi
10 bar/1 MPa/150 psi
1M
0 to 4 bar/400 kPa/60 psi
16.7 bar/1.67 MPa/250 psi
25 bar/2.5 MPa/375 psi
1P
0 to 10 bar/1 MPa/150 psi
26.7 bar/2.67 MPa/400 psi
40 bar/4 MPa/600 psi
1S
0 to 40 bar/4 MPa/600 psi
40 bar/4 MPa/600 psi
60 bar/6 MPa/900 psi
Sensors for negative overpressure
5C
–100 to 100 mbar/-10 to 10 kPa/
-1.5 to 1.5 psi
2.7 bar/270 kPa/40 psi
4 bar/400 kPa/60 psi
5F
–400 to 400 mbar/–40 to 40 kPa/–6 to 6 psi 5.3 bar/530 kPa/80 psi
8 bar/800 kPa/120 psi
5H
–1 to 1 bar/–100 to 100 kPa/–15 to 15 psi 6.7 bar/670 kPa/100 psi
10 bar/1 MPa/150 psi
5M
–1 to 4 bar/–100 to 400 kPa/–15 to 60 psi 16.7 bar/1.67 MPa/250 psi
25 bar/2.5 MPa/375 psi
5P
–1 to 10 bar/–0.1 to 1 MPa/–15 to 150 psi 26.7 bar/2.67 MPa/400 psi
40 bar/4 MPa/600 psi
Sensors for absolute pressure
2F
0 to 400 mbar/40 kPa/6 psi absolute
5.3 bar/530 kPa/40 psi
8 bar/800 kPa/120 psi
2H
0 to 1 bar/100 kPa/15 psi absolute
6.7 bar/670 kPa/80 psi
10 bar/1 MPa/150 psi
2M
0 to 4 bar/400 kPa/60 psi absolute
16.7 bar/1.67 MPa/250 psi
25 bar/2.5 MPa/375 psi
2P
0 to 10 bar/1 MPa/150 psi absolute
26.7 bar/2.67 MPa/400 psi
40 bar/4 MPa/600 psi
2S
0 to 40 bar/4 MPa/600 psi absolute
40 bar/4 MPa/600 psi
60 bar/6 MPa/900 psi
9Y
Special version, to be specified
40
Calibration; Unit:
1
0.2% sensor range; mbar/bar
2
0.2% sensor range; kPa/MPa
3
0.2 % sensor range; mmmH
2
O/mH
2
O
4
0.2% sensor range; inH
2
O/ftH
2
O
5
0.2% sensor range; kgf/cm
2
6
0.2% sensor range; psi
Summary of Contents for Cerabar M PMC41