Maintenance
ASP Station 2000 RPS20B
46
Hauser
11
Maintenance
11.1 Maintenance intervals
Hauser offers you a maintenance contract for your ASP Station 2000. A
maintenance contract increases the operational safety of your device and reduces your
staff's workload. Please contact your Hauser Service organization for more
detailed information on maintenance contracts.
No.
Designation
Minimum maintenance interval
1
2
5
6
4
3
A0023665
1
Membrane pump, set of gaskets 2 years
2
Air manager
2 years
3
Air filter
1 year
4
O-ring seals
1 year
5
Dosing glass
1 year
6
Diaphragm for hose clamp
1 year
11.2 Cleaning
11.2.1 Device
Only use cleaning agents that will definitely not damage the mechanical and electrical device
components. We recommend stainless steel cleaner for the cabinet body and water or soap, if
applicable, for the parts conveying medium. To ensure reliable operation, it is important to
clean the parts conveying medium regularly and thoroughly.
11.2.2 Parts conveying medium
All parts carrying medium can be dismantled and mounted easily without the need for
tools.