Mistral CCT Mirror

Safety Warnings

INSTRUCTION MANUAL

• 

This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE wiring regulations. 

It should be installed in accordance with local building regulations and is for domestic ceiling use only. 

•  Before installing your mirror always switch off the mains supply and remove the appropriate fuse or switch off the 

appropriate circuit breaker before commencing installation.

• 

This is a Class I product, and 

must

 be Earthed.

 The terminal blocks are supplied according to requirements of the 

fitting.

•  This product contain non-replaceable LEDs. If the LEDs stop working then the fitting must be replaced.

•  This product contains delicate parts – be careful during handling and maintenance to avoid breakage.

•  This fitting is heavy, and installation will be easier with the help of an assistant.

• 

This product has special protection against the ingress of water, and is rated IP44. 

• 

This mirror may be installed in Zones 1 and 2 and Outside Zones of 

a bathroom where water jets are not used for cleaning purposes. If 

installing in a bathroom, a 30mA RCD must be used in accordance 

with IEE Wiring Regulations and the Building Regulations. An 

electrician must be consulted if you are in any doubt about your 

own competency or meaning of bathroom “Zones”, “Equipotential 

Bonding” or “RCD”.

•  If any modification is made it will invalidate the warranty and may 

render the product unsafe.

Assembly/ User Instructions

Before you start

Please read these instructions carefully before fitting and retain for reference. Check the packaging and make sure 

that you have all the required parts. Follow each assembly step in order to prevent incorrect assembly. Ensure that the 

product is fully assembled as illustrated before use.

 

This mirror is suitable for use with the remote.

The mirror pack contains:

Mirror.

Fixing pack.

The following tools may be required:

Selection of cross and flat head screwdrivers.

Electric drill and assorted drill bits.

Wire strippers.

Care Information

Allow 10 minutes to cool before replacing, adjusting or cleaning.

Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.

OUTSIDE ZONES

ZONE

2

ZONE

1

0.6m

0.6m

2.25m

Ceiling

1. 

Always  switch  off  the  electricity  supply  at  the  mains  during  installation  and  maintenance.  We  recommend  that 

the fuse is withdrawn or circuit breaker switched off at the distribution board whilst work is in progress.  

 

Refer to Assembly Diagram 1.

 

2. 

This mirror fixes to the wall by locating the keyhole shaped slots over the mounting screws in the wall. It is important 

to get the screw positions correct to ensure easy and secure fitting. Measure the distance between the hole centres 

on the fixing lugs. Mark the positions of the screw holes on the wall. Check for concealed pipes and wiring before 

drilling. Use suitable drill bits for masonry and ceramic tiles. Supplied wall plugs are for solid walls only. For all other 

wall types ensure correct fixings are used. Fit appropriate wall fixings and fit supplied screws. Screw heads must 

protrude approx 3- 5mm from the wall to enable lugs to fit over adequately. 

Refer to Assembly Diagram 2.

These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.