Endon EL-40016 Instruction Manual Download Page 1

U13 02v3 

Endon Lighting,  

LS9 0SS 

 

 

 

INSTRUCTION MANUAL

 

 

 

PLEASE READ BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE 

REFERENCE 

 

 

 

 

 

The unit must be earthed. 

 

We recommend the use of a qualified electrician for all electrical installations. 

 

Installation must comply with current IEE Wiring Regulations and UK Building Regulations. 

 

Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-

F 1.0mm2 (not supplied). 

 

 

(1)

  

Switch off mains electrical supply before installation 

(2) 

Run cable (not supplied) from mains electrical supply to selected site, ensuring it is adequately 

protected through the full length of the cable run.  

Except where installed in a conduit or duct which provides equivalent protection against 

mechanical damage, a cable buried in the ground shall incorporate an earthed armour or metal 

sheath or both, suitable for use as a protective conductor, or be of insulated concentric 

construction. Buried cables shall be marked by cable covers or a suitable marking tape. Buried 

conduits and ducts shall be suitably identified. Buried cables, conduits and ducts shall be at a 

sufficient depth to avoid being damaged by any reasonably foreseeable disturbance of the 

ground. 

(3) 

Strip outer sheath from the end of supply cable from unit for a length of approximately 20mm and 

separate brown, blue and green yellow wires and bare the ends for a length of approximately 

5mm. 

(4) 

If fitted, remove decorative front cover (

See diagram, Page 2

). 

(5) 

Remove screw caps from outside of back plate and remove back plate from mounting plate. 

(6) 

Using the plastic mounting plate as a template, mark position of fixing holes.

 

(7) 

Drill holes and fit suitable fixing plugs.

 

(8) 

Pass the supply cable through the rubber grommet in the mounting plate.

 

 

(9) 

Connect the mains supply cable to the connector block as follows:

 

Incoming

 

Earth (Green/yellow wire) to terminal screw connector marked

 

Incoming Live (Brown or Red wire) to terminal block connector marked “L”. 

Incoming Neutral (Blue or Black wire) to terminal block connector marked “N”. 

 

(10) 

Ensure that the hexagon headed nuts are positioned securely at the rear of the back plate, and 

secure the back plate to the wall with suitable screws, ensuring that no wires are trapped or 

damaged.  

(11) 

Re- fit back plate to mounting plate, ensuring any seal is in place, and secure with screw caps. 

(12) 

Fit lamp bulb of type and wattage recommended on the lamp holder. Do not exceed maximum 

wattage indicated. 

(13) 

Re-fit decorative front cover. 

 

Replacement Lamps 

Should a lamp need to be replaced the user 

Must

 ensure that the replacements is a 240v 25W G9. 

Replacement lamps may be obtained from the stockist where you purchased this article. 

Switch on lantern and ensure it operates correctly. 

Clean only with damp cloth or soapy water. Do not use abrasive cleaners 

EL-40016 – Ferris Light 

Safety Warnings 

INSTALLATION 