Cambridge Wall Light
Safety Warnings
INSTRUCTION MANUAL
• This product is suitable for connection to 240V~50Hz supply, outside
or
in a bathroom location.
• It is recommended that this light be installed by a qualified electrician in accordance with current IEE Wiring
Regulations and Building Regulations (Part P).
• Before installing your light fitting always switch off the mains supply and remove the appropriate fuse or
switch off the appropriate circuit breaker before commencing installation.
• This is a Class I fitting, and
must
be connected to Earth.
The terminal blocks are supplied according to
requirements of the fitting.
• Never fit bulbs of a higher wattage than those specified on the label (as these may cause overheating and
damage the fitting).
• This product contains delicate parts. Take care during installation and maintenance to avoid breakages
• Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-F 1.0mm2
(not supplied) to selected site, ensuring it is adequately protected through the full length of the cable run, it
must come out of the flat surface of the wall or steps in line with the entry to the fitting.
• Except where installed in a conduit or duct which provides equivalent protection against mechanical damage,
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as
a protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable
covers or a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables,
conduits and ducts shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable
disturbance of the ground.
• This light may also be installed in “Zones 1 and 2 and Outside Zones” of a bathroom where water jets are
not
used for cleaning purposes. These zones are referenced in BS 7671:2008 “Requirements for Electrical
Installations”, IEE Wiring Regulations 17th Edition. All dimensions must be checked in conjunction with the
Regulations.
• The supply circuit must be protected by an RCD.
If installed in a bathroom
an RCD must be used
OR
the
casing of the light must be connected to the “Supplementary Equipotential Bonding” points in the bathroom.
• An electrician
must
be consulted if in any doubt about your own competency, or meaning of “Bathroom
Zones” or “Equipotential Bonding”.
• If any modification is made it will invalidate the warranty and may render the product unsafe.
• If the glass or diffuser is broken or cracked it must be replaced, please consult your retailer.
Endon Lighting, LS9 0SE
56216_56217-Cambridge-WB 20150908
Care Information
Allow 10 minutes to cool before replacing, adjusting or cleaning.
Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.
Assembly/ User Instructions
Please read these instructions carefully before fitting and retain for reference.
Check the packaging and make sure that you have all the required parts.
Follow each assembly step in order to prevent incorrect assembly.
Ensure that the product is fully assembled as illustrated before use.
Before you start