Endace Measurement Systems.
http://www.endace.com
EDM01.05-10r1 DAG 4.3S Card User Manual
23
Revision 6. 22 September 2005.
5.0 RUNNING DATA CAPTURE SOFTWARE
Introduction
For a typical measurement session, the
scripts/dag43start
script is
edited and used to operate the cards directly.
In this chapter
This chapter covers the following sections of information.
•
Starting Capture Session
•
High Load Performance
•
DAG Card Packet Transmission Capabilities
5.1 Starting Capture Session
Description
The various tools used for data capture are in the
tools
sub-directory.
For a typical measurement session, ensure the driver is loaded, the
firmware has been downloaded, and the card is configured.
The integrity of the card’s physical layer is then set and checked.
Procedure
Follow these steps to set a data capture session.
Process Description
Load Xilinx receive
image.
For a typical measurement session, first move to
the
dag
directory.
Load the driver.
Load the Xilinx receive image to each DAG. For
example, with two DAG 4.3S cards installed:
drv/dagload
dagrom -rvp –d dag0 -f xilinx/dag43pcix-terf.bit
dagrom -rvp –d dag1 -f xilinx/dag43pcix-terf.bit
Check integrity.
Set, and then check the integrity of the physical
layer to both DAGs as outlined in
.
dagfour –d dag0 default
dagfour –d dag1 default
Continued on next page