Using the Signal Strength Panel
The following diagram shows a typical radio network. A repeater is being used between the master
and remote radios because the distance between the master and the remote is too great for a
reliable connection.
The three radios have been provisioned with the settings shown in the following table.
Radio
Setting
Value
Master
Primary hop pattern
0
Network address
0
Unit address
0
Security key
0
Repeater
Primary hop pattern
0
Repeater hop pattern
1
Network address
0
Unit address
1
Security key
0
Remote
Primary hop pattern
1
Network address
0
Unit address
2
Summary of Contents for iPULSE R