Electrical Connection Guide
Attention!
Double-check all the wiring connections
before
supplying power to the
device. Failure to adhere to the following instructions can damage the device
and lead to hazardous conditions in and around the device!
Never handle the electrical connections with wet hands!
Before mounting the power input cable to the male connector, ensure the Ferrite (included with each
Electrolyser) is in place around the cable as close as possible to the male connector. The ferrite has an
internal diameter of 13.77 mm (350 Ohm, 150 MHz) and can simply be slid over the cable.
Connect the EL 2.1 as shown below to the socket labelled "Power". In the image below, brown is live,
blue is neutral, and the yellow/green is the ground. Follow the relevant safety standards and ensure
compliance with local and national regulations using the male connector in the correct orientation, as
shown below..
The EL2.1 has a thermomagnetic circuit breaker (C13) on the front panel, which protects the device
from overcurrent, and was selected according to IEC/EN 60898-1 and IEC/EN 60947-2.
However, we recommend installing a protective device against overload and short circuits on the
power supply line; it must be selected in relation to the devices maximum power consumption and in
L
(LIV
E)
N
(N
EU
TR
A
L)