Page 1: ...128 P Sales Inquiries Technical Support CarSense 303 L O G I C I N T E R F A C E 4564 Johnston Parkway Cleveland Ohio 44128 P 800 426 9912 F 216 518 9884 Sales Inquiries salessupport emxinc com Techni...

Page 2: ...ructions 1 Document no 10310404 Revision 1 6 5 30 17 Contents Cautions and Warnings 2 Product Overview 2 Specifications 3 Operation 3 Controls and Indicators 6 Connections 7 Troubleshooting 7 Installa...

Page 3: ...when using the CS303 as a closing detector on a parking arm operator to prevent accidental closing on a car Product Overview The CarSense 303 Logic Interface CS303 L works with CarSense 303 Direct Bur...

Page 4: ...otection Circuitry Reverse polarity and fuse protected Dimensions 73mm 2 9 x 38mm 1 2 x 78mm 3 1 Weight 0 25 lbs 113 g Connector 11 pin male connector JEDEC B11 88 NOTE Refer to CarSense 303 Operating...

Page 5: ...activates 4 Dual Relays Relay1 Active while Sensor1 is active Relay2 Active while Sensor1 is active 5 Common Relay Relay1 Active while Sensor1 or Sensor2 is active Relay2 500ms pulse when Sensor1 or S...

Page 6: ...s present Relay2 will be inactivate until the vehicle is undetected then Relay2 will activate for 500ms and then deactivate Dual Relays Dual Relays mode allows for the operation of both Relay1 and Rel...

Page 7: ...6 1 2 3 7 8 9 4 POWER RELAY 1 RELAY 2 Controls and Indicators CONFIGURATION SELECTOR Function Position 0 9 Discrete Relays 0 AB Directional Logic 1 Pulse on Entry 2 Pulse on Exit 3 Dual Relays 4 Commo...

Page 8: ...d setting 0 5 Red LED flashes relay clicks unstable Poor connection for Sensor1 or Sensor2 Check and fix connection If only one sensor is used set rotary switch to a valid position for 1 sensor Green...

Page 9: ...Directional Logic function the sensors should be installed 1 meter 40 apart in the axis of travel 4 When wiring the sensors to the CS303 L a The brown wire from both sensors goes to pin 11 on the CS3...

Page 10: ...lightning damage or use other than intended design There is no warranty of merchantability There are no warranties expressed or implied or any affirmation of fact or representation except as set forth...