background image

 

This product is an accessory or part of a system.

 

Always read and follow the manufacturer’s     

 

 

instructions for the equipment you are connecting 

this product to. Comply with all applicable codes and safety 
regulations. Failure to do so may result in damage, injury or 
death! 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

B

P

P

E

E

-

-

5

5

0

0

 

 

                                         Photo Beam with battery  
 

 

 

     powered Transmitter 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 
 
 

 

 

 

Not UL325 compliant  

 

 

 

 

 

 

 

 

 

 

Operating Instructions

 

 
 
 
 
 
 
 

 

 

Product Overview 

 The BPE-50 photo beam system uses 12 -24 VDC/AC on 
the transmitter and receiver with the transmitter offering the 
option of using the two 3.6 Volt batteries for power 
(included). 

Recommended battery replacement is the 

Varta 

ERAA 3V6 2400

 
 
 
 
 
 

 
 

Technical Specifications

 

 

 

Connections 

(Fig 1)

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Power Supply 

12-24 VDC 24 VAC (2-3.6 Volt Lithium 
Batteries for transmitter optional 
/included)  

 

Expected battery life  up to 2 years 
approx. 

 Current Draw 

RX = <50mA standby 100mA activated, TX 
= < 500uA 

 Relay Type 

2 Form C DPST contact rating .5A @ 24VDC 
/ 120VAC 

 Temperature                

-20C – 55C 

 Wavelength 

880 nm 

 Frequency 

High 90 Hz  Low 48 Hz  (Ext power 787 Hz) 

 Environmental 

IP 65 

 Detect Indicator  Red LED 
 Connector 

Terminal block 

 Relay contact 

0.5Amp  

 Housing Material  PA6 30% FG 
 Size 

H 4.4in (112mm) x W 2.05in (52mm) x D 
1.3in (33mm) 

 Range 

Up to 50 feet (if TX on 12/24 V 90 feet) 

 Detection Angle 

+/- 5% 

 Sensitivity 

Jumper J1 on receiver 

 Detection delay 

< 30 ms 

 Reset delay 

< 120 ms 

 

Transmitter 

Receiver 

Power Positive (+) 

Power Positive (+) 

Power Negative (-) 

Power Negative (-) 

NC Security Contact         

(join if not used) 

Internal Relay        

Normally Open 

Security edge                    

(join if not used)

 

Internal Relay        

Common 

Security edge                     

(join if not used)

 

Internal Relay        

Normally Closed Output 

Terminal connection as viewed from the front, left to right 

 

 

WARNING … 

Not to be used for Personnel Protection 

Never use product as sensing devices for personnel protection. 
Doing so could cause serious injury or death. 

 

These sensors do NOT include the self-checking redundant circuitry 

necessary to allow their use in personnel safety applications. A sensor failure or 
malfunction can cause either an energized or de-energized sensor output 
condition. UL 325 Non-compliant 

Reviews: