Troubleshooting Management
Connections
If a serial connection does not occur, cycle power by removing the
power cords, waiting for approximately 5 seconds, and then
reinstalling the power cords. In addition, check the terminal
session’s serial port parameters or replace the serial cable. (Make
sure it is a null modem cable, preferably the cable that shipped with
the switch.)
If the Ethernet activity LED is on, make sure you are using a cross-
over ethernet cable (unless using an ethernet hub), or check the IP
addresses on the switch and workstation as follows:
At a command line prompt, type
ping
DNSorIP
(where
DNSorIP
is
the switch’s DNS name or IP address) and press E
NTER
.
If a
“Reply from…”
or
“...is alive...”
message appears, the devices
can communicate.
If a
“Request timed out”
message appears (or the command
times out), the devices cannot communicate. Trace the cabling.
If needed, reconnect the devices.
Documentation
Links to the User’s Guide, Technical Briefs, and other product
documentation are available through the Web Manager.
To view the latest product documentation, click:
Help > Documentation
.
www.emulex.com
Corporate HQ
3333 Susan St., Costa Mesa, CA 92626 714.662.5600
Wokingham UK
(44) 118 977 2929 |
Paris FR
(33) 41 91 19 90
All names and trademarks are the property of their respective owners. ©2004 Emulex Corporation.
All Rights Reserved. Contents subject to change. 00041359-003_B 04-311 04/04
Quick Install Card
3-Step Setup
• Step 1: Installing & Powering On the Switch
• Step 2: Preparing a Network Interface
• Step 3: Initial Switch Setup
• Additional Information:
• Managing with the Intuitive Web Manager
• Documentation
• Troubleshooting Management Connections
Managing with the Intuitive
Web Manager
A quick list of frequent configuration tasks and their locations is
shown below.
To…
Click…
View switch status
Storage Switch
Change general switch configuration
Switch > Configuration
Change the IP Address
Switch > Configuration
Change the switch speed
Switch > Configuration
View the event log
Switch > Event Log
Upgrade the firmware
Switch > Files
Change the port settings
Port > Smart Settings
Configure zoning
Advanced Functions >
One Step Zoning
Reset the switch
Reboot
Emulex
®
Model 375
SAN Storage Switch