EMTRON ELC USER MANUAL
WWW.EMTRON.WORLD
© EMTRON AUSTRALIA PTY LTD MARCH 2018
5
2.0 Specification
Power Supply
▪
Operating Voltage: 7.0 to 22.0 Volts DC
▪
Operating Current Standby: 38mA at 14.0V
▪
Operating Current Average: 3A at 14.0V (Peak 8A Warmup)
▪
Reverse Battery Protection: 0mA current draw
▪
Battery Transient/Over Current Protection
Internal
▪
64MHz 16-bit Automotive Processor
Inputs
▪
Bosch LSU4.9. Supports Single or Dual Channel
▪
Resolution: 0.001 Lambda
▪
Range: 0.580 Lambda to open air.
▪
Lambda Signal sampling rate: 100 Hz
▪
Exhaust Pressure Pump Current Compensation
Communications
▪
CAN 2.0B Baud Rate: 250kBaud, 500kBaud or 1Mbaud Auto Detect
▪
CAN Transmit Rate 100Hz
Operating Temperature
▪
Operating Temperature Range: -30 to 85°C (-22 to 185°F)
Physical
ELC2M
▪
Enclosure Size 52 mm x 74 mm x 18 mm
▪
125g (Excludes loom)
ELC1/ ELC2
▪
Enclosure Size 63mm x 54 mm x 20mm
▪
ELC1 165g, ELC2 200g (includes flying loom)