2. Operation
2-1. Camera install Position.
- Install preparation : Windows 10/64bit PC, tripod, fence, Queue belt, table, stop sign, etc.
- Measurement distance: Measurement distance varies depending on the camera lens angle.
- Measuring distance : [30 degree : 1 ~ 4 M] / [50 degree : 1 ~ 3M] / [90 degree : 1 ~ 2M].
- Camera position :
(Important) Install the camera in a place where the wind is not directly
exposed. external wind/air conditioner/fan/heater, etc.)
- Big Hall (Exhibition hall, Shopping mall, etc.) : 30 degree lens(MT30-3) recommended.
- Metro station (train station, airport, bus terminal, etc.): 30 degree lens(MT30-3) recommended.
- Narrow tunnels (path, stairs, escalators, elevators, etc.): 90 degree lens(MT30-9) recommended.
- Building entrance (religious facilities, small building entrance, general hospital, school, kindergarten, etc.) :
90 / 50 degree lens(MT30-9 / MT30-5) recommended.
- Store entrance (indoor gym, clinic, shop, restaurant, etc.): 90 / 50 degree lens(MT30-9 / MT30-5) recommended.
- How to fix the camera :
- Camera fixing method : [Fixed to the wall or ceiling using a wall bracket], [Installed on the floor using a tripod for camera].
- Dual display method : [No Monitor], [Windows Monitor], [D HDMI Sp 2 Monitors].
[Operation 2/3]
STOP
[Preparation for installation]
[Entrance]
Gate
Hall
Queue
Line
Measuring
line
Moving Line
[Narrow Path]
Moving Line
[Wall/Ceiling fix]
[Tripod fix]
Gate
Hall
gate
Hall
[Curved Path]
indoor
7/ 10