Pre Installation

4 Power Device 

To unlock, insert a 1.5mm 

Allen key  into the Allen 

key slot and turn 

anticlockwise as shown.

3 Fix Mounting Plate

2

 

Components

device

unpowered

(pins unlinked)

device

powered

(both pins linked) 

!

Installation must conform to applicable local installation 

codes and should only be installed by a fully trained 

competent person. 

Ensure that the device is installed as per the site survey.

The use of a non-metallic spacer should be considered if 

mounting the device on to a metal surface.

Do NOT Press the Log On button on a pre-programmed 

device. This will cause communication with the Control Panel 

to be lost. Should this happen, delete the device from the 

system and add it back on.

Detector

Wireless Module inc 300mm cable

Mounting Plate

Remove the mounting plate from the wireless module, by turning 

it anticlockwise. 

5 Optional Device Locking

6 Configuration

To lock the detector into 

the wireless module, 

insert a 1.5mm Allen key 

into the allen key slot and 

turn clockwise as shown.

Use both mounting holes to ensure a firm fixing.

Use suitable fasteners and fixings.

Once powered, reassemble the device.

The device’s loop address is configured within the menu structure 

of the Radio Hub.

Refer to the programming manual (Doc Ref: MK98) for full 

programming information. 

Free to download from 

www.emsgroup.co.uk

Wireless Detector c/w Remote Indicator

Installation Guide

FCX-100-101  Optical Smoke Detector & Remote Indicator Unit   

[2][3]

FCX-120-101  Heat A1R Detector c/w Remote Indicator Unit       

 

[1][3]

                    

FCX-120-111  Heat CS Detector c/w Remote Indicator Unit         

[1][3]

                  

FCX-170-101  Wireless Detector Base c/w Remote Indicator Unit    

 

 

[3]

  

5-RIM          Remote Indicator Unit Only

Example shown:

Model FCX-100-101

Part No     Product Description

See the Specification section for compliance information.

CPR

SIZE AA

SIZE AA

SIZE AA

SIZE AA

SIZE AA

SIZE AA

ATTENTION

OBSERVE PRECAUTIONS

FOR HANDLING

ELECTROSTATIC

SENSITIVE

5

6

Dust Cover

4

OBSERVE CORRECT POLARITY, USING SPECIFIED BATTERIES. 

If fitting / re-fitting batteries; observe correct polarity, using 

only specified batteries.

Connect the power jumper across the PIN header.

w

w

w

.emsg

r

oup

.c

o

.uk

R

adio D

et

ec

t

or Base

PRESS 

HERE T

O

L

OG ON

IDENT

2

3

1

5

6

4

7

Front Cover

Mounting Plate

2

3

7

Fixing Screws

1

Remote Indicator Unit

Wireless Detector 

©2018 EMS Ltd. All rights reserved                                                                       Page 1 of 2 

TSD033  Iss 3  05/09/2018   AJM

www.emsgroup.co.uk

Radio Detector Base

PRESS  HERE TO

LOG ON

IDENT

Reviews: